access icon free Fast B1 field localisation in high-field MRI systems

In high-magnetic magnetic resonance imaging (MRI) systems (7 T and above), the radio frequency (RF) field shows greater inhomogeneity compared with clinical MRI systems (1.5 and 3.0 T). In multi-channel RF coils, driving each coil element with convex optimisation can reduce non-uniformity of the RF field in a region of interest. In this Letter, a periodic compressed method (PCM) and a PCM after averaging are proposed in order to reduce RF coil control time at high fields. Simulation results were obtained using a human head model in 7 and 9.4 T systems, and the results are discussed in detail.

Inspec keywords: biomedical MRI; brain; optimisation; medical image processing; image coding; coils; data compression

Other keywords: human head model; fast B1 field localisation; region-of-interest; magnetic flux density 3.0 T; high-magnetic magnetic resonance imaging systems; convex optimisation; coil element; high-field MRI systems; periodic compressed method; magnetic flux density 1.5 T to 9.4 T; clinical MRI systems; multichannel RF coils; radiofrequency field

Subjects: Medical magnetic resonance imaging and spectroscopy; Optimisation techniques; Patient diagnostic methods and instrumentation; Optimisation techniques; Biophysics of neurophysiological processes; Biomedical magnetic resonance imaging and spectroscopy; Image and video coding; Biology and medical computing; Computer vision and image processing techniques; Codes

References

    1. 1)
      • 1. Vaughan, J., Garwood, M., Collins, C.M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M.B., Ug˘urbil, K.: ‘7 T vs. 4 T: RF power, homogeneity, and signal-to-noise comparison in head images’, Magn. Reson. Med., 2001, 46, (1), pp. 2430 (doi: 10.1002/mrm.1156).
    2. 2)
      • 2. Vaughan, J., DelaBarre, L., Snyder, C., Tian, J., Akgun, C., Shrivastava, D., Liu, W., Olson, C., Adriany, G., Strupp, J., Anderson, P., Gopinath, A., Moortele, P.: ‘9.4 T human MRI: preliminary results’, Magn. Reson. Med., 2006, 56, pp. 12741282 (doi: 10.1002/mrm.21073).
    3. 3)
      • 4. Brunner, D., Pruessmann, K.: ‘B1+ interferometry for the calibration of RF transmitter arrays’, Magn. Reson. Med., 2009, 61, pp. 14801488 (doi: 10.1002/mrm.21893).
    4. 4)
      • 3. Yoo, H., Gopinath, A., Vaughan, J.T.: ‘A method to localize RF B1 field in high-field magnetic resonance imaging systems’, IEEE Trans. Biomed. Eng., 2012, 59, (12), pp. 33653371 (doi: 10.1109/TBME.2012.2208965).
    5. 5)
      • 5. Lustig, M., Donoho, D., Santos, J., Pauly, J.: ‘Compressed sensing MRI’, IEEE Signal Process. Mag., 2008, 25, (2), pp. 7282 (doi: 10.1109/MSP.2007.914728).
http://iet.metastore.ingenta.com/content/journals/10.1049/el.2013.1335
Loading

Related content

content/journals/10.1049/el.2013.1335
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
Correspondence
This article has following corresponding article(s):
interview