Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

access icon free Three-dimensional high-speed optical coherence tomography system using KTN swept light source

Three-dimensional (3D) optical coherence tomography (3D-OCT) has attracted attention for visualising complex structures in the biomedical field. In this reported work, a high-speed 3D-OCT system is developed, which is based on a high-speed swept light source and a Mach-Zehnder interferometer with a high-speed photodetector. The light source, incorporating a KTa1–x Nb x O3 electro-optic deflector, operates at a repetition rate of 200 kHz and enables high-speed data acquisition. As a preliminary study, images of a strawberry's surface have been obtained, two- and three-dimensionally. The 3D-OCT system has potential for the construction of a four-dimensional OCT image to dynamically display 3D-OCT images.

References

    1. 1)
      • 7. Toyoda, S., Fujiura, K., Sasaura, M., Enbutsu, K., Tate, A., Shimokozono, M., Fushimi, H., Imai, T., Manabe, K., Matsuura, T., Kurihara, T.: ‘Low-driving-voltage electro-optic modulator with novel KTa1 − xNbxO3 crystal waveguides’, Jpn. J. Appl. Phys., 2004, 43, 8B, pp. 58625866 (doi: 10.1143/JJAP.43.5862).
    2. 2)
      • 5. Okabe, Y., Sasaki, Y., Ueno, M., Sakamoto, T., Toyoda, S., Yagi, S., Naganuma, K., Fujiura, K., Sakai, Y., Kobayashi, J., Omiya, K., Ohmi, M., Haruna, M.: ‘200 kHz swept light source equipped with KTN deflector for optical coherence tomography’, Electron. Lett., 2012, 48, (4), pp. 201202 (doi: 10.1049/el.2011.4057).
    3. 3)
      • 2. Yun, S.H., Tearney, G.J., de Boer, J.F., Iftimia, N., Bouma, B.E.: ‘High-speed optical frequency-domain imaging’, Opt. Express, 2003, 11, (22), pp. 29532963 (doi: 10.1364/OE.11.002953).
    4. 4)
      • 1. Chinn, S.R., Swanson, E.A., Fujimoto, J.G.: ‘Optical coherence tomography using a frequency-tunable optical source’, Opt. Lett., 1997, 22, (5), pp. 340342 (doi: 10.1364/OL.22.000340).
    5. 5)
      • 4. Yasuno, Y., Madjarova, V.D., Makita, S., Akiba, M., Morosawa, A., Chong, C., Sakai, T., Chan, K., Itoh, M., Yatagai, T.: ‘Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments’, Opt. Express, 2005, 13, (26), pp. 1065210664 (doi: 10.1364/OPEX.13.010652).
    6. 6)
      • 3. Blatter, C., Weingast, J., Alex, A., Grajciar, B., Wieser, W., Drexler, W., Huber, R., Leitgeb, R.A.: ‘In situ structural and microangiographic assessment of human skin lesions with high-speed OCT’, Biomed. Opt. Express, 2012, 3, (10), pp. 26362646. (doi: 10.1364/BOE.3.002636).
    7. 7)
      • 6. Miyazu, J., Imai, T., Toyoda, S., Sasaura, M., Yagi, S., Kato, K., Sasaki, Y., Fujiura, K.: ‘New beam scanning model for high-speed operation using KTa1–xNbxO3 crystals’, Appl. Phys. Express, 2011, 4, (11), pp. 1501 (doi: 10.1143/APEX.4.111501).
http://iet.metastore.ingenta.com/content/journals/10.1049/el.2013.0843
Loading

Related content

content/journals/10.1049/el.2013.0843
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
Correspondence
This article has following corresponding article(s):
in brief
This is a required field
Please enter a valid email address