MEASUREMENT AND CALIBRATION METHOD OF ACELERATION SENSOR FOR PAVEMENT DEFLECTION MEASUREMENT UNDER IMPACT LOAD
MEASUREMENT AND CALIBRATION METHOD OF ACELERATION SENSOR FOR PAVEMENT DEFLECTION MEASUREMENT UNDER IMPACT LOAD
- Author(s): G. Dou 1 ; L. Liu 2 ; N. Miao 3 ; B. Zhang 4
- DOI: 10.1049/icp.2021.1309
For access to this article, please select a purchase option:
Buy conference paper PDF
Buy Knowledge Pack
IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.
Thank you
Your recommendation has been sent to your librarian.
- Author(s): G. Dou 1 ; L. Liu 2 ; N. Miao 3 ; B. Zhang 4
-
-
View affiliations
-
Affiliations:
1:
Research institute of highway ministry of transport, No. 8 Xitucheng Road, Haidian District , Beijing , China ;
2: Research institute of highway ministry of transport, No. 8 Xitucheng Road, Haidian District , Beijing , China ;
3: Research institute of highway ministry of transport, No. 8 Xitucheng Road, Haidian District , Beijing , China ;
4: Research institute of highway ministry of transport, No. 8 Xitucheng Road, Haidian District , Beijing , China
Source:
The 8th International Symposium on Test Automation & Instrumentation (ISTAI 2020),
2021
p.
181 – 187
-
Affiliations:
1:
Research institute of highway ministry of transport, No. 8 Xitucheng Road, Haidian District , Beijing , China ;
- Conference: The 8th International Symposium on Test Automation & Instrumentation (ISTAI 2020)
- DOI: 10.1049/icp.2021.1309
- ISBN: 978-1-83953-506-2
- Location: Online Conference
- Conference date: 28-29 November 2020
- Format: PDF
The pavement deflection under impact load is measured by acceleration sensor. Generally, the calibration parameters of this kind of acceleration sensor are sensitivity amplitude, frequency response characteristics, etc., so it is impossible to evaluate the accuracy and repeatability of sensor deformation measurement in specific engineering application scenarios. In this paper, a calibration method based on periodic vibration platform is proposed, which can effectively meet the technical requirements of evaluating the accuracy of deformation. It has a good reference value for the application scenarios of micro deformation measurement in the field of road engineering.
Inspec keywords: deformation; vibration measurement; roads; calibration; acceleration measurement; sensors
Subjects: Measurement of mechanical variables; Sensing devices and transducers; Velocity, acceleration and rotation measurement; Mechanical variables measurement; Measurement standards and calibration; Sensing and detecting devices; Velocity, acceleration and rotation measurement; Measurement standards and calibration