The study of generator inter-fault based on the digital and physical simulation
The study of generator inter-fault based on the digital and physical simulation
- Author(s): Chen Deshu ; Yin Xianggen ; Zhang Zhe ; Chen Wei ; Xia Yongjun
- DOI: 10.1049/cp:20062199
For access to this article, please select a purchase option:
Buy conference paper PDF
Buy Knowledge Pack
IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.
7th IET International Conference on Advances in Power System Control, Operation and Management (APSCOM 2006) — Recommend this title to your library
Thank you
Your recommendation has been sent to your librarian.
- Author(s): Chen Deshu ; Yin Xianggen ; Zhang Zhe ; Chen Wei ; Xia Yongjun Source: 7th IET International Conference on Advances in Power System Control, Operation and Management (APSCOM 2006), 2006 page ()
- Conference: 7th IET International Conference on Advances in Power System Control, Operation and Management (APSCOM 2006)
- DOI: 10.1049/cp:20062199
- ISBN: 0 86341 246 7
- Location: Hong Kong, China
- Conference date: 30 Oct.-2 Nov. 2006
- Format: PDF
The power generator is important and precious apparatus in the power system. The protective relay must operate the circuit breaker instantaneously with high sensitivity when the fault occurs in the generator. According to previous research, the fault current of inter-fault in some situation is very large. But on the other faults, the fault current of inter-fault is so small that it is difficult to be identified by relay. The construction of large capacity generators, especially for hydroelectric power generator, is very complicated and differences each other. Besides that the difficulty and complicate exist in the calculation of the fault quantity and analysis of the sensitivity of the protection scheme, the difficulty exists in the verification the correctness of calculation algorithm too. In this paper, it was introduced the researching result about the inter-fault of the power generator both using the methods based on digital simulation and physical simulation. At the end of this paper, the comparison of these two methods was given. It shows the digital and physical simulation modes using in this paper can be used in the works of design, operation and research. (5 pages)
Inspec keywords: fault currents; circuit breakers; hydroelectric generators
Subjects: Hydroelectric power stations and plants; Switchgear; a.c. machines
Related content
content/conferences/10.1049/cp_20062199
pub_keyword,iet_inspecKeyword,pub_concept
6
6