Pll-less SRF Technique for Operation of SAPF Under Unbalanced and Distorted Supply Voltage
Pll-less SRF Technique for Operation of SAPF Under Unbalanced and Distorted Supply Voltage
- Author(s): Y. Hoon ; M.A.M. Radzi ; M.K. Hassan ; N.F. Mailah
- DOI: 10.1049/cp.2018.1313
For access to this article, please select a purchase option:
Buy conference paper PDF
Buy Knowledge Pack
IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.
5th IET International Conference on Clean Energy and Technology (CEAT2018) — Recommend this title to your library
Thank you
Your recommendation has been sent to your librarian.
- Author(s): Y. Hoon ; M.A.M. Radzi ; M.K. Hassan ; N.F. Mailah Source: 5th IET International Conference on Clean Energy and Technology (CEAT2018), 2018 page (8 pp.)
- Conference: 5th IET International Conference on Clean Energy and Technology (CEAT2018)
- DOI: 10.1049/cp.2018.1313
- ISBN: 978-1-83953-003-6
- Location: Kuala Lumpur, Malaysia
- Conference date: 5-6 Sept. 2018
- Format: PDF
Shunt active power filter (SAPF) has been recognized as a feasible solution to current harmonics issues. In its controller, due to structure simplicity, synchronous reference frame (SRF) technique is best suited to be applied in generating reference current. However, the existing SRF algorithm performs inefficiently due to limitations of numerical low-pass filter (LPF). Besides, the existing algorithm is as yet considered to have excessive features which are not required in the procedure of generating reference current. Most importantly, its dependency on traditional phase-locked loop (PLL) has greatly degraded its effectiveness when the source voltage is unbalanced and/or distorted. Therefore, this paper presents a PLL-less SRF algorithm for generating reference current to effectively control performance of a SAPF developed based on three-level neutral-point-clamped (NPC) inverter. Specifically, three notable refinements are implemented: (1) eliminate the traditional use of LPF by replacing it with a mathematical-based average current detector; (2) reduce algorithm complexity by removing excessive features; (3) eliminate synchronization error of PLL by integrating a new self-tuning-filter (STF)-based synchronization technique. The proposed algorithm is created and assessed in MATLAB-Simulink. Simulation and experimental results are provided, demonstrating superiority of the proposed PLL-less SRF algorithm over the existing SRF algorithm.
Inspec keywords: low-pass filters; synchronisation; power harmonic filters; invertors; phase locked loops; active filters
Subjects: Power supply quality and harmonics; DC-AC power convertors (invertors)