http://iet.metastore.ingenta.com
1887

Voltage-source inverter-fed drives

Voltage-source inverter-fed drives

For access to this article, please select a purchase option:

Buy chapter PDF
£10.00
(plus tax if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
Diagnosis and Fault Tolerance of Electrical Machines, Power Electronics and Drives — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The authors discuss condition monitoring, fault diagnosis and prognosis of electrical machines, eccentricity faults, stator inter-turn faults, broken rotor bars or end-rings, demagnetisation of permanent magnets, bearing faults, torque monitoring, magnetic flux monitoring, single-phase rotation test, thermal stress, electrical stress, mechanical stress, fault diagnostic techniques, current-based approaches, voltage-based approaches, fault-tolerant techniques, phase connection and neutral connection to capacitors midpoint, phase connection and neutral connection to an extra invertor leg, series VSI topologies.

Chapter Contents:

  • 2.1 Condition monitoring, fault diagnosis and prognosis of electrical machines
  • 2.1.1 Introduction
  • 2.1.2 Condition monitoring, fault diagnosis and prognosis
  • 2.1.3 Fault diagnosis of electrical machines
  • 2.1.3.1 The eccentricity fault
  • 2.1.3.2 The stator inter-turn fault
  • 2.1.3.3 Broken rotor bars or end-rings
  • 2.1.3.4 Demagnetisation of permanent magnets
  • 2.1.3.5 Bearing faults
  • 2.1.4 Alternative diagnostic methods
  • 2.1.4.1 Electromagnetic/mechanical torque monitoring
  • 2.1.4.2 Magnetic flux monitoring
  • 2.1.4.3 Single-phase rotation test
  • 2.1.5 Fault prognosis of electrical machines
  • 2.1.5.1 Thermal stress
  • 2.1.5.2 Electrical stress
  • 2.1.5.3 Mechanical stress
  • 2.1.5.4 Discussion
  • 2.2 Fault diagnostic techniques applied to voltage source inverter-fed drives
  • 2.2.1 Introduction
  • 2.2.2 Fault diagnostic approaches
  • 2.2.2.1 Current-based approaches
  • 2.2.2.2 Voltage-based approaches
  • 2.3 Fault-tolerant techniques applied to VSI-fed drives
  • 2.3.1 Introduction
  • 2.3.2 Non-redundant topologies
  • 2.3.2.1 Phase connection to capacitors midpoint
  • 2.3.2.2 Neutral connection to capacitors midpoint
  • 2.3.3 Redundant topologies
  • 2.3.3.1 Phase connection to an extra inverter leg
  • 2.3.3.2 Neutral connection to an extra inverter leg
  • 2.3.3.3 Series VSI topologies
  • Acknowledgement
  • References

Inspec keywords: voltage-source convertors; condition monitoring; fault diagnosis; electric drives; fault tolerance; invertors

Other keywords: magnetic flux monitoring; voltage-source inverter-fed drives; fault-tolerant techniques; current-based approaches; condition monitoring; voltage-based approaches; bearing faults; broken rotor bars; series VSI topologies; eccentricity faults; permanent magnets; demagnetisation; neutral connection; electrical machines; fault diagnosis; fault diagnostic techniques; stator inter-turn faults; end-rings; torque monitoring; electrical stress; single-phase rotation test; fault prognosis; capacitors midpoint; extra invertor leg; thermal stress; mechanical stress; phase connection

Subjects: Power electronics, supply and supervisory circuits; Drives

Preview this chapter:
Zoom in
Zoomout

Voltage-source inverter-fed drives, Page 1 of 2

| /docserver/preview/fulltext/books/po/pbpo126e/PBPO126E_ch2-1.gif /docserver/preview/fulltext/books/po/pbpo126e/PBPO126E_ch2-2.gif

Related content

content/books/10.1049/pbpo126e_ch2
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address