Electromagnetic inductance tomography (EMT): sensor, electronics and image reconstruction algorithm for a system with a rotatable parallel excitation field

Buy article PDF

Abstract

The main features and principle of operation of an electromagnetic inductance tomography system are described. The system can image the distribution of electrically conducting and/or magnetically permeable materials and is analogous to the other electrical tomography systems which measure capacitance or resistance. The paper presents a nonintrusive system with a rotatable parallel uniform excitation magnetic field which improves the detectability at the centre of the object space with respect to that near the periphery. The sensor construction, electronics design and image reconstruction are described. A novel electronic compensation scheme is used to condition the output signals from the sensor. This scheme subtracts the empty space background field measurements and consequently increases the overall dynamic range of the data acquisition system. An image reconstruction technique based on a correlation method is described and some images are presented.

References

    1. 1)
      • Beck, M.S., Hoyle, B.S., Morris, M.A., Waterfall, R.C., Williams, R.A.: `Process tomography1995: Implementation for industrial processes', 4th workshop on European concerted action on Process tomography, March 1995, Bergen, Norway
    2. 2)
      • Xie, C.G., Grattan, K.T.V., Augousti, A.T.: Review of process tomography image reconstruction methods, Sensors VI: Technology, systems and applications, 1993, (IOP publishing), p. 341-346
    3. 3)
      • Dickin, F.J., Hoyle, B.S., Hunt, A., Huang, S.M., Ilyas, O., Lenn, C., Waterfall, R.C., Williams, R.A., Xie, C.G., Beck, M.S.: `Tomographic imaging ofindustrial process equipment, techniques and applications', IEE Proc. G, 1992, 139, (1), p. 72-82
    4. 4)
      • Yu, Z.Z., Peyton, A.J., Beck, M.S., Xu, L.A.: `Electromagnetic tomography (EMT): A new process imaging system', Proceedings of Sensor and applications VI, 12–15 Sept. 1993, IOP Publishing, Manchester, UK, p. 347–352
    5. 5)
      • Al-Zeibak, S., Saunders, N.H.: `Feasibility study of in vivo electromagnetic imaging', Phys. Med. Biol., 1993, 38, p. 151-160
    6. 6)
      • Huang, S.M., Xie, C.G., Thorn, R., Snowden, D., Beck, M.S.: `Design of sensor electronicsfor electrical capacitance tomography', IEE Proc. G, 1992, 139, (1), p. 83-88
    7. 7)
      • Xie, C.G., Huang, S.M., Hoyle, B.S., Thorn, R., Lenn, C., Snowden, D., Beck, M.S.: `Electrical capacitance tomography for flow imaging, system model fordevelopment of image reconstruction algorithms and design of primary sensors', IEE Proc. G, 1992, 139, (1), p. 89-98
    8. 8)
    9. 9)
      • Peyton, A.J., Yu, Z.Z., Lyon, G.M., Al-Zeibak, S., Xiong, H.L., Borges, A.R., Saunders, N.H., Beck, M.S.: `An overview of electromagnetic inductancetomography, description of three different systems', Meas. Sci. & Technol., 1996, 7, p. 216-271
    10. 10)
      • Wang, M., Dickin, F.J., Williams, R.A.: `Modelling and analysis of electricallyconductive vessels and pipelines in electrical resistance process tomography', IEE Proc. Sci. Meas. Technol., 1995, 142, (4), p. 313-322
    11. 11)
      • Gisser, D.G., Isaacson, D., Newell, J.C.: `Current topics in impedance imaging', Clin. Phys. Physiol. Meas., 1987, p. A 39-46
    12. 12)
      • Yu, Z.Z.: `Non-intrusive inductance based electromagnetic tomography (EMT)techniques for process imaging', 1994, PhD, UMIST, UK
    13. 13)
      • Peyton, A.J., Yu, Z.Z., Al-Zeibak, S., Saunders, N.H., Borges, A.R.: `Electromagnetic imaging using mutual inductance tomography, potentialforprocess applications', Particles & Particle Syst. Character., 1995, 12, p. 68-74
    14. 14)
      • Rektorys, K.: Survey of applicable mathematics, 1969 (Illiffe Books)
This is a required field