Park-based and zero sequence-based relaying techniques with application to transformers protection

Park-based and zero sequence-based relaying techniques with application to transformers protection

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IEE Proceedings - Generation, Transmission and Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

Two relaying techniques for protecting power transformers are presented and discussed. Very often, differential relaying is used for this purpose. A comparison between the two proposed techniques and conventional differential relaying is thus presented. The first technique, based on the measurements of zero sequence current within a delta winding, performs best in multiwinding transformers, since only measurement of the coil currents is needed. Thus, great simplicity is achieved. The second one is based on the differential procedure, but its analysis of asymmetries in the plot in Park's plane avoids problems related to spectral analysis in conventional differential relaying. The technique is justified from the analysis of symmetrical components. Misoperation in conventional differential relaying has been observed in some cases as a function of switching instant and fault location. This issue is discussed in the paper, and a statistical analysis of a large number of laboratory tests, in which both factors were controlled, is presented. As a conclusion, both relaying techniques proposed succeed in protecting the transformer. Additionally, the Park-based relay exhibits three characteristics of most importance: fastest performance, robustness and simplicity in its formulation.

References

    1. 1)
      • H. Shang , J.F. Wen , P. Liu , O.P. Malik . Discrimination between fault and magnetizing inrush current in transformers using short-time correlation transform. Electr. Power Energy Syst. , 557 - 562
    2. 2)
      • G.D. Rockefeller . Fault protection with a digital computer. IEEE Trans. Power Appar. Syst. , 438 - 464
    3. 3)
      • C. Rusell . (1956) The art and science of protective relaying.
    4. 4)
      • Sidhu, T.S., Gill, H.S., Sachdev, M.S.: `A transformer protection technique with immunity to CT saturation and ratio-mismatch conditions', Proc IEEE Canadian Conf. on Electrical and Computer Engineering (CCECE), May 1998, Toronto, 1, p. 24–28.
    5. 5)
      • M.R. Rao , B.P. Singh . Detection and localization of interturn fault in the HV winding of a power transformer using wavelets. IEEE Trans. Dielectr. Electr. Insul. , 4 , 652 - 657
    6. 6)
      • A. Guzmán , S. Zocholl , G. Benmouyal , H.J. Altuve . A current-based solution for transformer differential protection- Part I: problem statement. IEEE Trans. Power Deliv. , 4 , 485 - 491
    7. 7)
    8. 8)
      • C. Parameswariah , M. Cox . Frequency characteristics of wavelets. IEEE Transac. Power Deliv. , 3 , 800 - 804
    9. 9)
    10. 10)
    11. 11)
    12. 12)
    13. 13)
      • B. Grčar , D. Dolinar . Integrated digital power transformer protection. IEE Proc. Gener., Transm. Distrib. , 4 , 323 - 328
    14. 14)
      • M. Gómez-Morante , D.W. Nicoletti . A wavelet-based differential transformer protection. IEEE Trans. Power Deliv. , 4 , 1351 - 1358
    15. 15)
    16. 16)
    17. 17)
      • M.R. Zaman , M.A. Rahman . Experimental testing of the artificial neural network based protection of power transformers. IEEE Trans. Power Deliv. , 2 , 510 - 517
    18. 18)
      • P.L. Mao , R.K. Aggarwal . A novel approach to the classification of the transient phenomena in power transformers using combined wavelet transform and neural network. IEEE Trans. Power Syst. , 4 , 654 - 660
    19. 19)
      • F.J. Harris . On the use of windows for harmonic analysis with the discrete Fourier transform. Proc. IEEE , 1 , 51 - 84
    20. 20)
      • Díaz, G., Barbón, A., Gómez-Aleixandre, J.: `Evaluating interturn shortcircuits through the analysis of line current sequences', Proc. 15th Int. Conf. on Electric Machines (ICEM), August 2002, Brugge, paper 155.