http://iet.metastore.ingenta.com
1887

Virtual inertia optimisation control of DFIG and assessment of equivalent inertia time constant of power grid

Virtual inertia optimisation control of DFIG and assessment of equivalent inertia time constant of power grid

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Renewable Power Generation — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

Due to decoupling between mechanical part and electrical part of doubly fed induction generator (DFIG), the DFIG has no natural frequency response capability, which results in decreasing of total rotary inertia of power grid, and the frequency stability of power grid will face larger challenges. This study proposes an assessment method of equivalent inertia time constant, further gives the assessment value of equivalent inertia time constant of DFIG. Then, a virtual inertia optimisation control of DFIG using rotor current direct control based on status assessment value is proposed, which includes conventional function, status assessment and additional virtual inertia control. The assessment values of equivalent inertia time constant of wind farms, synchronous generator and power grid connected with multi-type generators are calculated, which are related to penetration of wind power and control strategies. The simulation results verify the efficacious of the proposed virtual inertia optimisation control and the accuracy of assessment method of equivalent inertia time constant, and the frequency stability of power grid is improved in the condition of different active power of wind farms and penetration of wind power.

http://iet.metastore.ingenta.com/content/journals/10.1049/iet-rpg.2018.5063
Loading

Related content

content/journals/10.1049/iet-rpg.2018.5063
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address