http://iet.metastore.ingenta.com
1887

Accurate active islanding detection method for grid-tied inverters in distributed generation

Accurate active islanding detection method for grid-tied inverters in distributed generation

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Renewable Power Generation — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

An accurate active islanding detection method for grid-tied inverters in distributed generation using phase disturbance based on grid synchronisation is presented in this study. To have good performance on both power quality and islanding detection, a third-harmonic injection is generated by a new kind of phase disturbance and the scope of phase disturbance coefficient is precisely defined, besides, for extracting the third-harmonic component at the point of common coupling accurately, a selective harmonic extraction based on multiple second-order generalised integrators is also provided. Performances of the proposed method have been studied and confirmed through extensive simulations using MATLAB/Simulink platform.

References

    1. 1)
      • S. Dhar , P.K. Dash .
        1. Dhar, S., Dash, P.K.: ‘Performance analysis of a new fast negative sequence power injection oriented islanding detection technique for photovoltaic based voltage source converter based micro grid operation’, IET Gener. Transm. Distrib., 2015, 9, (15), pp. 20792090.
        . IET Gener. Transm. Distrib. , 15 , 2079 - 2090
    2. 2)
      • (2000)
        2. IEEE Recommended Practice for Utility Interface of Photovoltaic (PV) Systems, IEEE Std 929-2000, 2000, doi:10.1109/IEEESTD.2000.91304.
        .
    3. 3)
      • H. Pourbabak , A. Kazemi .
        3. Pourbabak, H., Kazemi, A.: ‘Islanding detection method based on a new approach to voltage phase angle of constant power inverters’, IET Gener. Transm. Distrib., 2016, 10, (5), pp. 11901198.
        . IET Gener. Transm. Distrib. , 5 , 1190 - 1198
    4. 4)
      • T. Basso .
        4. Basso, T.: ‘IEEE standard for interconnecting distributed resources with the electric power system’. IEEE PES Meeting, 2004, p. 1.
        . IEEE PES Meeting , 1
    5. 5)
      • Y. Shang , S. Shi .
        5. Shang, Y., Shi, S.: ‘Islanding detection method adopting single-phase-operating circuit breaker’, IET Gener. Transm. Distrib., 2016, 10, (4), pp. 10391047.
        . IET Gener. Transm. Distrib. , 4 , 1039 - 1047
    6. 6)
      • (2003)
        6. IEEE Std. 1547-2003: ‘IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems’. 2003.
        .
    7. 7)
      • S. Li , A.J. Rodolakis , K. El-Arroudi .
        7. Li, S., Rodolakis, A.J., El-Arroudi, K., et al: ‘Islanding protection of multiple distributed resources under adverse islanding conditions’, IET Gener. Transm. Distrib., 2016, 10, (8), pp. 19011912.
        . IET Gener. Transm. Distrib. , 8 , 1901 - 1912
    8. 8)
      • H.T. Do , X. Zhang , N.V. Nguyen .
        8. Do, H.T., Zhang, X., Nguyen, N.V., et al: ‘Passive-islanding detection method using the wavelet packet transform in grid-connected photovoltaic systems’, IEEE Trans. Power Electron., 2016, 30, (10), pp. 69556967.
        . IEEE Trans. Power Electron. , 10 , 6955 - 6967
    9. 9)
      • W. Cai , B. Liu , S. Duan .
        9. Cai, W., Liu, B., Duan, S., et al: ‘An islanding detection method based on dual-frequency harmonic current injection under grid impedance unbalanced condition’, IEEE Trans. Ind. Inf., 2013, 9, (2), pp. 11781187.
        . IEEE Trans. Ind. Inf. , 2 , 1178 - 1187
    10. 10)
      • K. Hotta , A. Kitamura , M. Okamoto .
        10. Hotta, K., Kitamura, A., Okamoto, M., et al: ‘Islanding prevention measures: Demonstration testing at Rokko test center for advanced energy systems’. Proc. 23rd Annu. IEEE Power Electron. Specialist Conf., 1993, pp. 10631067.
        . Proc. 23rd Annu. IEEE Power Electron. Specialist Conf. , 1063 - 1067
    11. 11)
      • W. Xu , G. Zhang , C. Li .
        11. Xu, W., Zhang, G., Li, C., et al: ‘A power line signaling based technique for anti-islanding protection of distributed generators—Part I: scheme and analysis’, IEEE Trans. Power Deliv., 2007, 22, (3), pp. 17581766.
        . IEEE Trans. Power Deliv. , 3 , 1758 - 1766
    12. 12)
      • 12. Report IEAPVPS T5–09: ‘Evaluation of islanding detection methods for photovoltaic utility interactive power systems’. Int. Energy Agency Implementing agreement on Photovoltaic Power Systems, 2002, U.S.A.
        . Int. Energy Agency Implementing agreement on Photovoltaic Power Systems
    13. 13)
      • T. Funabashi , K. Koyanagi , R. Yokoyama .
        13. Funabashi, T., Koyanagi, K., Yokoyama, R.: ‘A review of islanding detection methods for distributed resources’. Proc. IEEE Power Tech., Italy, 2003, vol. 2, p. 6.
        . Proc. IEEE Power Tech. , 6
    14. 14)
      • D.D. Reigosa , F. Briz , C.B. Charro .
        14. Reigosa, D.D., Briz, F., Charro, C.B., et al: ‘Active islanding detection using high-frequency signal injection’, IEEE Trans. Ind. Appl., 2012, 48, (5), pp. 15881597.
        . IEEE Trans. Ind. Appl. , 5 , 1588 - 1597
    15. 15)
      • S.I. Jang , K.H. Kim .
        15. Jang, S.I., Kim, K.H.: ‘An islanding detection method for distributed generations using voltage unbalance and total harmonic distortion of current’, IEEE Trans. Power Del., 2004, 19, (2), pp. 745752.
        . IEEE Trans. Power Del. , 2 , 745 - 752
    16. 16)
      • B. Singam , L.Y. Hui .
        16. Singam, B., Hui, L.Y.: ‘Assessing SMS and PJD schemes of anti-islanding with varying quality factor’. Proc. IEEE Int. Power Energy Conf., 2006, pp. 196201.
        . Proc. IEEE Int. Power Energy Conf. , 196 - 201
    17. 17)
      • J.C.M. Vieira , W. Freitas , Z. Huang .
        17. Vieira, J.C.M., Freitas, W., Huang, Z., et al: ‘Formulas for predicting the dynamic performance of ROCOF relays for embedded generation applications’, IEE Proc. Gener. Transm. Distrib., 2006, 153, (4), pp. 399406.
        . IEE Proc. Gener. Transm. Distrib. , 4 , 399 - 406
    18. 18)
      • A. Samui , S.R. Samantaray .
        18. Samui, A., Samantaray, S.R.: ‘Assessment of ROCPAD relay for islanding detection in distributed generation’, IEEE Trans. Smart Grid, 2011, 2, (2), pp. 391398.
        . IEEE Trans. Smart Grid , 2 , 391 - 398
    19. 19)
      • W. Freitas , X. Wilsun , C.M. Affonso .
        19. Freitas, W., Wilsun, X., Affonso, C.M., et al: ‘Comparative analysis between ROCOF and vector surge relays for distributed generation applications’, IEEE Trans. Power Deliv., 2005, 20, (2), pp. 13151324.
        . IEEE Trans. Power Deliv. , 2 , 1315 - 1324
    20. 20)
      • P. O'Kane , B. Fox .
        20. O'Kane, P., Fox, B.: ‘Loss of mains detection for embedded generation by system impedance monitoring’. Sixth Int. Conf. on Developments in Power System Protection (Publ.434), 1997, pp. 9598.
        . Sixth Int. Conf. on Developments in Power System Protection (Publ.434) , 95 - 98
    21. 21)
      • T. Yang , L. Wang , C. Zhang .
        21. Yang, T., Wang, L., Zhang, C., et al: ‘A novel islanding detection method based on positive feedback between reactive current and frequency’, Autom. Electr. Power Syst., 2012, 36, (14), pp. 193199.
        . Autom. Electr. Power Syst. , 14 , 193 - 199
    22. 22)
      • L.A.C. Lopes , Z. Yongzheng .
        22. Lopes, L.A.C., Yongzheng, Z.: ‘Islanding detection assessment of multi-inverter systems with active frequency drifting methods’, IEEE Trans. Power Deliv., 2008, 23, pp. 480486.
        . IEEE Trans. Power Deliv. , 480 - 486
    23. 23)
      • J.E. Kim , J.S. Hwang .
        23. Kim, J.E., Hwang, J.S.: ‘Islanding detection method of distributed generation units connected to power distribution system’. Int. Conf. on Power System Technology, 2000. Proc. PowerCon 2000, 2000, vol. 2, pp. 643647.
        . Int. Conf. on Power System Technology, 2000. Proc. PowerCon 2000 , 643 - 647
    24. 24)
      • D. Velasco , C. Trujillo , G. Garcera .
        24. Velasco, D., Trujillo, C., Garcera, G., et al: ‘An active anti-islanding method based on phase-PLL perturbation’, IEEE Trans. Power Electron., 2011, 26, (4), pp. 10561066.
        . IEEE Trans. Power Electron. , 4 , 1056 - 1066
    25. 25)
      • M. Ciobotaru , V.G. Agelidis , R. Teodorescu .
        25. Ciobotaru, M., Agelidis, V.G., Teodorescu, R., et al: ‘Accurate and less-disturbing active anti-islanding method based on PLL for grid-connected converters’, IEEE Trans. Power Electron., 2010, 25, (6), pp. 15761584.
        . IEEE Trans. Power Electron. , 6 , 1576 - 1584
    26. 26)
      • P. Rodríguez , A. Luna , I. Candela .
        26. Rodríguez, P., Luna, A., Candela, I., et al: ‘Multiresonant frequency-locked loop for grid synchronization of power converters under distorted grid conditions’, IEEE Trans. Ind. Electron., 2011, 58, (1), pp. 127138.
        . IEEE Trans. Ind. Electron. , 1 , 127 - 138
    27. 27)
      • J. Matas , M. Castilla , J. Miret .
        27. Matas, J., Castilla, M., Miret, J., et al: ‘An adaptive prefiltering method to improve the speed/accuracy tradeoff of voltage sequence detection methods under adverse grid conditions’, IEEE Trans. Ind. Electron., 2014, 61, (5), pp. 21392151.
        . IEEE Trans. Ind. Electron. , 5 , 2139 - 2151
    28. 28)
      • R. Teodorescu , M. Liserre , P. Rodríguez . (2011)
        28. Teodorescu, R., Liserre, M., Rodríguez, P.: ‘Grid converters for photovoltaic and wind power systems’ (John Wiley & Sons, New York, 2011), pp. 3142.
        .
    29. 29)
      • S. Golestan , M. Monfared , F.D. Freijedo .
        29. Golestan, S., Monfared, M., Freijedo, F.D., et al: ‘Performance improvement of a pre-filtered synchronous-reference-frame PLL by using a PID-type loop filter’, IEEE Trans. Ind. Electron., 2014, 61, (7), pp. 34693479.
        . IEEE Trans. Ind. Electron. , 7 , 3469 - 3479
    30. 30)
      • A. Elrayyah , Y. Sozer , M. Elbuluk .
        30. Elrayyah, A., Sozer, Y., Elbuluk, M.: ‘Robust phase locked-loop algorithm for single-phase utility-interactive inverters’, IET Power Electron., 2014, 7, (5), pp. 10641072.
        . IET Power Electron. , 5 , 1064 - 1072
    31. 31)
      • S. Golestan , M. Monfared , F.D. Freijedo .
        31. Golestan, S., Monfared, M., Freijedo, F.D.: ‘Design-oriented study of advanced synchronous reference frame phase-locked loops’, IEEE Trans. Power Electron., 2013, 28, (2), pp. 765778.
        . IEEE Trans. Power Electron. , 2 , 765 - 778
    32. 32)
      • M.K. Ghartemani , S.A. Khajehoddin , P.K. Jain .
        32. Ghartemani, M.K., Khajehoddin, S.A., Jain, P.K., et al: ‘Addressing DC component in PLL and notch filter algorithms’, IEEE Trans. Power Electron., 2012, 27, (1), pp. 7886.
        . IEEE Trans. Power Electron. , 1 , 78 - 86
    33. 33)
      • P. Rodriguez , A. Luna , I. Candela .
        33. Rodriguez, P., Luna, A., Candela, I., et al: ‘Grid synchronization of power converters using multiple second order generalized integrators’. Proc. IECON'08, 2008, pp. 755760.
        . Proc. IECON'08 , 755 - 760
    34. 34)
      • J. Matas , M. Castilla , L.G. Vicuna .
        34. Matas, J., Castilla, M., Vicuna, L.G., et al: ‘Fast grid synchronization technique based on a multiple cascaded general integrator scheme for distributed generation inverters’. Proc. ISIE'12, 2012, pp. 10031010.
        . Proc. ISIE'12 , 1003 - 1010
    35. 35)
      • J.H. Kim , J.G. Kim , Y.H. Ji .
        35. Kim, J.H., Kim, J.G., Ji, Y.H., et al: ‘An islanding detection method for a grid-connected system based on the Goertzel algorithm’, IEEE Trans. Power Electron., 2011, 26, (4), pp. 10491055.
        . IEEE Trans. Power Electron. , 4 , 1049 - 1055
    36. 36)
      • C. Limsakul , A. Sangwang , D. Chenvidhya .
        36. Limsakul, C., Sangwang, A., Chenvidhya, D., et al: ‘An impedance model of a PV grid-connected system’. Proc. Photovoltaic Specialist Conf., 2008, pp. 14.
        . Proc. Photovoltaic Specialist Conf. , 1 - 4
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-rpg.2017.0080
Loading

Related content

content/journals/10.1049/iet-rpg.2017.0080
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address