Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

access icon free Loss-of-excitation analysis and protection for pumped-storage machines during starting

The reversible synchronous machines in a pumped station are put into operation frequently for effective operation of the hydro pumped-storage system. The detection of loss-of-excitation (LOE), which is a common failure for synchronous machines, must be guaranteed not only in normal operation, but also under starting and other possible operation conditions. A model of pumped-storage units under the starting condition was developed using the SimPowerSystems in Matlab/Simulink. The simulation results and real tests of a pumped-storage power plant in northeast China were presented. The LOE characteristics during starting were analysed for the first time. Since the frequency of voltage and current runs up gradually from zero to the rated frequency during starting, conventional LOE protections based on impedance under the rated frequency have to be disabled during starting. For this reason, a novel LOE protection was developed based on the R–L time-domain model and the least-square algorithm. Theoretical analysis and simulation tests demonstrate that the proposed LOE protection method is correct and valid.

References

    1. 1)
      • 3. Anagnostopoulos, J.S., Papantonis, D.E.: ‘Pumping station design for a pumped-storage wind-hydro power plant’, Energy Convers. Manage., 2007, 48, (11), pp. 30003017.
    2. 2)
    3. 3)
      • 20. IEEE Std C37.102TM-2006: ‘IEEE guide for AC generator protection’, 2006.
    4. 4)
    5. 5)
    6. 6)
    7. 7)
    8. 8)
    9. 9)
    10. 10)
    11. 11)
    12. 12)
    13. 13)
    14. 14)
    15. 15)
    16. 16)
    17. 17)
    18. 18)
      • 16. SIPROTEC – Multifunctional machine protection 7UM62 manual’, Siemens Ltd., 2005.
    19. 19)
      • 19. Lipo, T.A.: ‘Analysis of synchronous machines’ (CRC Press, Salem, MA, 2012).
    20. 20)
      • 10. Mason, C.R.: ‘A new loss-of-excitation relay for synchronous generators’, AIEE Trans. III, Power Appar. Syst., 1949, 68, pp. 12401245.
    21. 21)
      • 3. Anagnostopoulos, J.S., Papantonis, D.E.: ‘Pumping station design for a pumped-storage wind-hydro power plant’, Energy Convers. Manage., 2007, 48, (11), pp. 30003017.
    22. 22)
    23. 23)
    24. 24)
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-rpg.2015.0013
Loading

Related content

content/journals/10.1049/iet-rpg.2015.0013
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address