access icon free Converter rating optimisation for a brushless doubly fed induction generator

This article studies the converter rating requirement of a Brushless doubly-fed induction generator (DFIG) for wind turbine applications. Practical constraints such as the generator torque-speed requirement, reactive power management and grid low-voltage ride-through (LVRT) are considered. Experimental data have been used to obtain a realistic system model of a Brushless DFIG in a wind turbine. The study shows that there is a minimum converter rating, dependant on operating point, but this may not be achievable without machine derating. The use of a capacitor bank enables the converter ratings to be reduced without compromising the machine's performance. The effect of the machine's leakage inductance on the interplay of LVRT, achievable system power factor, converter rating and losses is investigated.

Inspec keywords: reactive power; power system management; wind turbines; power grids; asynchronous generators; brushless machines; power capacitors; power convertors

Other keywords: LVRT; machine leakage inductance; DFIG; wind turbine application; reactive power management; machine derating; capacitor bank; grid low-voltage ride-through; generator torque-speed requirement; converter rating requirement optimisation; brushless doubly fed induction generator

Subjects: Power convertors and power supplies to apparatus; Wind power plants; Power system management, operation and economics; Asynchronous machines

References

    1. 1)
    2. 2)
      • 11. McMahon, R.A., Tavner, P., Abdi, E., Malliband, P., Barker, D.: ‘Characterising brushless doubly fed machine rotors’, IET Electr. Power Appl., 2010, 7, pp. 16.
    3. 3)
      • 2. Long, T., Shao, S., Abdi, E., et al: ‘Symmetrical low voltage ride-through of a 250kW Brushless DFIG’. Sixth IET Int. Conf. on Power Electronics, Machines and Drives (PEMD), Bristol, UK, March 2012, pp. 16.
    4. 4)
      • 13. Abdi, E., Oraee, A., Abdi, S., McMahon, R.A.: ‘Design of the Brushless DFIG for optimal inverter rating’. Seventh IET Int. Conf. on Power Electronics, Machines and Drives (PEMD), Manchester, UK, April 2014, pp. 16.
    5. 5)
    6. 6)
      • 10. Shao, S., Abdi, E., McMahon, R.: ‘Dynamic analysis of the brushless doubly-fed induction generator during symmetrical three-phase voltage dips’. Int. Conf. on Power Electronics and Drive Systems, Taipei, Taiwan, November 2009, pp. 464469.
    7. 7)
      • 4. Wang, X., Roberts, P., McMahon, R.A.: ‘Studies of inverter ratings of BDFM adjustable speed drive or generator systems’. Int. Conf. on Power Electronics and Drives Systems, 2005, vol. 1, pp. 337342.
    8. 8)
      • 12. Abdi, S., Abdi, E., Oraee, A., McMahon, R.: ‘Investigation of magnetic wedge effects in large-scale BDFMs’. IET Renewable Power Generation Conf., Beijing, China, September 2013, pp. 14.
    9. 9)
    10. 10)
      • 5. Carlson, R., Voltolini, H., Runcos, F., Kuo-Peng, P., Batistela, N.J.: ‘Performance analysis with power factor compensation of a 75 kw brushless doubly fed induction generator prototype’. IEEE Int. Electric Machines and Drives Conf., Antalya, Turkey, May 2007, pp. 15021507.
    11. 11)
      • 6. Byars, R.: ‘Power system architecture: finding the best solution for a 5MW wind turbine’. EWEA Offshore Wind Conf., Amsterdam, Netherlands, November 2011.
    12. 12)
      • 1. McMahon, R., Wang, X., Abdi, E., Tavner, P., Roberts, P., Jagiela, M.: ‘The BDFM as a Generator in Wind Turbines’. Power Electronics and Motion Control Conf., Portoroz, Slovenia, 2006, pp. 18591865.
    13. 13)
      • 8. ‘Requirements for offshore Grid Connections in the E.ON Netz Network’, http://www.eon-netz.com/pages/ehn_de/Veroeffentlichungen/Netzanschluss/Netzanschlussregeln/080702ENENAROS2008eng.pdf, updated 1 April 2008.
    14. 14)
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-rpg.2014.0249
Loading

Related content

content/journals/10.1049/iet-rpg.2014.0249
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading