© The Institution of Engineering and Technology
This article studies the converter rating requirement of a Brushless doubly-fed induction generator (DFIG) for wind turbine applications. Practical constraints such as the generator torque-speed requirement, reactive power management and grid low-voltage ride-through (LVRT) are considered. Experimental data have been used to obtain a realistic system model of a Brushless DFIG in a wind turbine. The study shows that there is a minimum converter rating, dependant on operating point, but this may not be achievable without machine derating. The use of a capacitor bank enables the converter ratings to be reduced without compromising the machine's performance. The effect of the machine's leakage inductance on the interplay of LVRT, achievable system power factor, converter rating and losses is investigated.
References
-
-
1)
-
9. Piwko, R., Miller, N., Girad, R., MacDowell, J., Clark, K.: ‘Generator fault tolerance and grid codes’, IEEE Power Energy Mag., 2010, 8, pp. 18–26 (doi: 10.1109/MPE.2009.935560).
-
2)
-
11. McMahon, R.A., Tavner, P., Abdi, E., Malliband, P., Barker, D.: ‘Characterising brushless doubly fed machine rotors’, IET Electr. Power Appl., 2010, 7, pp. 1–6.
-
3)
-
2. Long, T., Shao, S., Abdi, E., et al: ‘Symmetrical low voltage ride-through of a 250kW Brushless DFIG’. Sixth IET Int. Conf. on Power Electronics, Machines and Drives (PEMD), Bristol, UK, March 2012, pp. 1–6.
-
4)
-
13. Abdi, E., Oraee, A., Abdi, S., McMahon, R.A.: ‘Design of the Brushless DFIG for optimal inverter rating’. Seventh IET Int. Conf. on Power Electronics, Machines and Drives (PEMD), Manchester, UK, April 2014, pp. 1–6.
-
5)
-
14. Tohidi, S., Tavner, P., McMahon, R.A., et al: ‘Low voltage ride-through of DFIG and brushless DFIG: similarities and differences’, Electr. Power Syst. Res., 2014, 110, pp. 64–72 (doi: 10.1016/j.epsr.2013.12.018).
-
6)
-
10. Shao, S., Abdi, E., McMahon, R.: ‘Dynamic analysis of the brushless doubly-fed induction generator during symmetrical three-phase voltage dips’. Int. Conf. on Power Electronics and Drive Systems, Taipei, Taiwan, November 2009, pp. 464–469.
-
7)
-
4. Wang, X., Roberts, P., McMahon, R.A.: ‘Studies of inverter ratings of BDFM adjustable speed drive or generator systems’. Int. Conf. on Power Electronics and Drives Systems, 2005, vol. 1, pp. 337–342.
-
8)
-
12. Abdi, S., Abdi, E., Oraee, A., McMahon, R.: ‘Investigation of magnetic wedge effects in large-scale BDFMs’. IET Renewable Power Generation Conf., Beijing, China, September 2013, pp. 1–4.
-
9)
-
H. Polinder ,
F.F.A. Van Der Pijl ,
G.J. De Vilder
.
Comparison of direct-drive and geared generator concepts for wind turbines.
IEEE Trans. Energy Convers.
,
725 -
733
-
10)
-
5. Carlson, R., Voltolini, H., Runcos, F., Kuo-Peng, P., Batistela, N.J.: ‘Performance analysis with power factor compensation of a 75 kw brushless doubly fed induction generator prototype’. IEEE Int. Electric Machines and Drives Conf., Antalya, Turkey, May 2007, pp. 1502–1507.
-
11)
-
6. Byars, R.: ‘Power system architecture: finding the best solution for a 5MW wind turbine’. EWEA Offshore Wind Conf., Amsterdam, Netherlands, November 2011.
-
12)
-
1. McMahon, R., Wang, X., Abdi, E., Tavner, P., Roberts, P., Jagiela, M.: ‘The BDFM as a Generator in Wind Turbines’. Power Electronics and Motion Control Conf., Portoroz, Slovenia, 2006, pp. 1859–1865.
-
13)
-
14)
-
7. Abdi, E., McMahon, R., Malliband, P., et al: ‘Performance analysis and testing of a 250kW medium-speed brushless doubly-fed induction generator’, IET Renew. Power Gener., 2013, 7, pp. 631–638 (doi: 10.1049/iet-rpg.2012.0234).
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-rpg.2014.0249
Related content
content/journals/10.1049/iet-rpg.2014.0249
pub_keyword,iet_inspecKeyword,pub_concept
6
6