Lightning protection of wind turbines – a comparison of measured data with required protection levels
Lightning protection of wind turbines – a comparison of measured data with required protection levels
- Author(s): V. Peesapati ; I. Cotton ; T. Sorensen ; T. Krogh ; N. Kokkinos
- DOI: 10.1049/iet-rpg.2008.0107
For access to this article, please select a purchase option:
Buy article PDF
Buy Knowledge Pack
IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.
Thank you
Your recommendation has been sent to your librarian.
- Author(s): V. Peesapati 1 ; I. Cotton 1 ; T. Sorensen 2 ; T. Krogh 3 ; N. Kokkinos 4
-
-
View affiliations
-
Affiliations:
1: Electrical and Electronic Engineering, University of Manchester, Manchester, UK
2: Electrical and Electronic Engineering, DONG Energy, Copenhagen, Denmark
3: Electrical and Electronic Engineering, For Siemens, Wind Power Electricon A/S, Herning, Denmark
4: Electrical and Electronic Engineering, Elemko SA, Metamorphosis, Greece
-
Affiliations:
1: Electrical and Electronic Engineering, University of Manchester, Manchester, UK
- Source:
Volume 5, Issue 1,
January 2011,
p.
48 – 57
DOI: 10.1049/iet-rpg.2008.0107 , Print ISSN 1752-1416, Online ISSN 1752-1424
Latest wind turbine lightning protection systems have been refined to the point where lightning damage is now relatively rare. This is increasingly important as wind turbines move offshore where access for maintenance is more difficult than for most land-based wind farms. Manufacturers have been trying to make sure that the lightning protection systems they install comply with the highest protection levels stipulated in the relevant IEC standards. In this study, data from the Nysted Offshore Wind farm in Denmark and that from a large number of other wind turbines worldwide is reviewed to show the range of lightning currents that have been measured on wind turbines currently in operation. These current values are compared with the required protection levels within the standards.
Inspec keywords: power generation protection; wind turbines; lightning protection
Other keywords:
Subjects: Wind power plants; Power system protection
References
-
-
1)
- Alonso, M.A., Irastorza, D.C.: `Dynamic wind turbine lightning protection behaviour under strom conditions', 29thInt. Conf. on Lightning Protection, 2008.
-
2)
- BS EN 62305-1: ‘Protection against lightning – Part 1: general principles’. 2006.
-
3)
- Alonso, M.A., Larrion, I.A.: `Calculation of electric fields in a wind mill due to a lightning discharge using finite elements method', Int. Conf. on Lightning Protection, 2004, Avignon, France.
-
4)
- A.J. Eriksson . The incidence of lightning strikes to power lines. IEEE Trans. Power Deliv. , 3 , 859 - 870
-
5)
- T. Sorensen , F.V. Jensen , N. Raben , J. Lykkegaard , J. Saxov . Lightning protection for offshore wind farms.
-
6)
- T. Naka , J.N. Vasa , S. Yokoyama . Study on lightning protection methods for wind turbine blades. IEE J. Trans. , 10
-
7)
- 61400–24, I.: ‘Wind turbine generator systems – Part 24: lightning protection for wind turbines’. June 2000.
-
8)
- LM Lightning Protection: 2006, http://www.lmwindpower.com/Blades/Products/Lightning.aspx.
-
9)
- Sorenson, T.S., Blas Hermoso, J.A.P., Montanya, J.: `The update of IEC 61400–24 lightning protection of wind turbines', 29thInt. Conf. on Lightning Protection of Wind Turbines, 2008.
-
10)
- K.A. Berger , R.B.A. Kröninger . Parameters of lightning flashes. Cigré , 41 , 23 - 37
-
11)
- F. Fuchs , R. Schmid , J. Weisinger . Lightning current and magnetic field parameters caused by lightning strikes to tall structures relating to interference of electronic systems. IEEE Trans. Electromagn. Compat. , 4 , 444 - 451
-
12)
- Sceibe, K., Axmann, T., Birk, C.: `Lightning research for offshore wind farms in the North Sea', 29thInt. Conf. on Lightning Protection, 2008.
-
13)
- Project FINO 3: Available at http://www.fino3.de/Joomla/index.php.
-
14)
- WWEA: ‘120 Gigawatt of wind turbines globally contribute to secure electricity generation’. 2009 [cited 16/10/2009].
-
15)
- A.M. Rizk . A model for switching impulse leader inception and breakdown of long air-gaps. IEEE Trans. Power Deliv. , 1 , 596 - 606
-
16)
- Bertelsen, K., Erichsen, H.V., Madsen, S.F.: `Application of numerical models to determine lightning attachment points on wind turbines', ICLP, 2007.
-
17)
- GWEC: ‘Global wind energy outlook’, 2006.
-
18)
- V.A. Rakov , M.A. Uman . Lightning – physics and effects.
-
19)
- Sørensen, T., Johansen, P., Olsen, M.L.: `Lightning strike sensor for power producing wind turbines', European Wind Energy Conf. Exhibition, 1999, Nice, France.
-
20)
- K. Berger . Novel observations on lightning discharges: results of research on Mount San Salvatore. J. Franklin Inst. , 6 , 478 - 525
-
21)
- J. Schoene , M.A. Uman , M. Aurele . (2005) Testing of the OBO Bettermann peak current sensor system for Lawrence Livermore National Laboratory.
-
22)
- T. Naka , J.N. Vasa , S. Yokoyama . Experimental studies on lightning protection design for wind turbine blades.
-
23)
- M. Durstewitz . (2001) Wind Energy Report Germany 2001; Annual Evaluation of WMEP.
-
24)
- Montanya, J., Rachidi, F., Rubinstein, M., Bermudez, J.L., Sola, G., Hermoso, B.: `Protection of large wind turbine blades against lightning', 29thInt. Conf. on Lightning Protection (ICLP), 2008, Uppsala, Sweden.
-
25)
- F. Rachidi , M. Montanya , J. Bermudez . A review of current issues in lightning protection of new-generation wind-turbine blades. IEEE Trans. Ind. Electron. , 6 , 2489 - 2496
-
26)
- R.B. Anderson , A.J. Eriksson . Lightning parameters for engineering application. Cigré Electra , 65 - 102
-
27)
- McNiff, B.: `Wind Turbine Lightning Protection Project NREL Subcontractor Report No. SR-500-31115', 2002.
-
28)
- K. Miyake , T. Suzuki , M. Takashima . Winter lightning on Japan sea coast-lightning striking frequency total structures. IEEE Trans. Power Deliv. , 3 , 1370 - 1376
-
29)
- I. Cotton , N. Hatziargyriou , M. Lorentzou . Lightning protection of wind turbines – a designers guide to best practice.
-
30)
- Aguado, M., Hermoso, B., Martinez-cid, P.: `Risks assessment for lightnings strokes in wind farm installations', High Voltage Engineering Symp., 1999, 2, p. 357–360.
-
31)
- http://www.obo-bettermann.com/en/pdf_kataloge.shtml, accessed 2007.
-
32)
- L. Rademakers , H. Wessels , R. Lok . Lightning damage of OWECS (Part 1: ‘parameters relevant for cost modelling’)'. 2002.
-
33)
- http://www.jomitek.dk/, accessed January 2008.
-
1)