http://iet.metastore.ingenta.com
1887

Low-cost direct instantaneous torque control for switched reluctance motors with bus current detection under soft-chopping mode

Low-cost direct instantaneous torque control for switched reluctance motors with bus current detection under soft-chopping mode

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Power Electronics — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

This study proposed a low-cost torque distribution function (TSF)-based direct instantaneous torque control (DITC) technique for switched reluctance motors (SRMs) by bus current detection under soft-chopping mode. A three-phase 12/8-pole prototype SRM is employed to analyse the phase currents and operation states, and a new converter connection with bus current sensor placement strategy is presented to replace the phase current sensors in each phase leg. Considering that the conventional bus current contains both the chopping current and demagnetisation current, the current sensor is placed in a new bus to remove all the needless demagnetisation currents. To obtain the chopping current information from the bus current for DITC implementation, pulse-width modulation signals with extremely short turn-off time are injected into the lower transistors to insert the chopping current detection states for brief intervals during each fundamental frequency cycle. The DITC scheme is implemented directly on the detected chopping currents from bus current based on a sinusoidal TSF. The proposed DITC system is more compact and low cost by using just a bus current sensor. The effectiveness of the proposed technique is verified by the simulation and experimental results.

References

    1. 1)
    2. 2)
    3. 3)
    4. 4)
    5. 5)
    6. 6)
    7. 7)
    8. 8)
    9. 9)
    10. 10)
    11. 11)
    12. 12)
    13. 13)
    14. 14)
    15. 15)
    16. 16)
    17. 17)
    18. 18)
    19. 19)
    20. 20)
    21. 21)
    22. 22)
    23. 23)
    24. 24)
    25. 25)
    26. 26)
    27. 27)
    28. 28)
    29. 29)
    30. 30)
    31. 31)
    32. 32)
    33. 33)
    34. 34)
    35. 35)
    36. 36)
    37. 37)
    38. 38)
    39. 39)
    40. 40)
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-pel.2015.0370
Loading

Related content

content/journals/10.1049/iet-pel.2015.0370
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address