© The Institution of Engineering and Technology
This study concentrates on the load disturbance in voltage-controlled three-phase voltage source inverter (VSI) with transformer. High power density could be obtained when the transformer placed behind the inductor–capacitor (LC) filter, but the voltage drop on transformer leakage impedance may reduce output voltage quality in high power application. Load current feedforward control is applied to reduce output impedance and suppress load disturbance. To avoid the non-ideal high-frequency noise introduced by full feedforward strategy, simplified feedforward strategy is proposed to improve dynamic performance. The feedforward strategies implemented in both stationary frame and synchronous frame are derived, and the reduction of output impedance is analysed in detail. The distinct features of the proposed feedforward strategies are error-free steady-state fundamental output, fast dynamic response and convenient implementation. Finally, simulation and experimental results are provided to verify feasibility and validity of the proposed control strategy.
References
-
-
1)
-
A. Kawamura ,
R.G. Hoft
.
Instantaneous feedback controlled PWM inverter with adaptive hysteresis.
IEEE Trans. Ind. Appl.
,
7 ,
769 -
775
-
2)
-
5. Ho, C.N., Chung, H.S.: ‘Implementation and performance evaluation of a fast dynamic control scheme for capacitor-supported interline DVR’, IEEE Trans. Power Electron., 2010, 25, (8), pp. 1975–1988 (doi: 10.1109/TPEL.2010.2044587).
-
3)
-
10. Sha, D., Wu, D., Liao, X.: ‘Analysis of a hybrid controlled three-phase grid-connected inverter with harmonics compensation in synchronous reference frame’, IET Power Electron., 2012, 4, (7), pp. 743–751 (doi: 10.1049/iet-pel.2010.0231).
-
4)
-
M.J. Ryan ,
W.E. Brumsickle ,
R.D. Lorenz
.
Control topology options for single-phase UPS inverters.
IEEE Trans. Ind. Appl.
,
2 ,
493 -
501
-
5)
-
D.N. Zmood ,
D.G. Holmes ,
G. Bode
.
Frequency domain analysis of three-phase linear current regulator.
IEEE Trans. Ind. Appl.
,
2 ,
601 -
610
-
6)
-
4. Tamyurek, B.: ‘A high-performance SPWM controller for three-phase UPS systems operating under highly nonlinear loads’, IEEE Trans. Power Electron., 2013, 28, (8), pp. 3689–3701 (doi: 10.1109/TPEL.2012.2227817).
-
7)
-
P.C. Loh ,
D.G. Holmes
.
Analysis of multiloop control strategies for LC/Cl/LCL-filtered voltage-source and current source inverters.
IEEE Trans. Ind. Appl.
,
2 ,
644 -
654
-
8)
-
14. Hasanzadeh, A., Edrington, C.S., Maghsoudlou, B., Fleming, F., Mokhtari, H.: ‘Multi-loop linear resonant voltage source inverter controller design for distorted loads using the linear quadratic regulator method’, IET Power Electron., 2012, 5, (6), pp. 841–851 (doi: 10.1049/iet-pel.2011.0400).
-
9)
-
4. Dannehl, J., Fuchs, F., Hansen, S., Thøgersen, P.B.: ‘Investigation of active damping approaches for PI-based current control of grid-connected pulse width modulation converters with LCL filters’, IEEE Trans. Ind. Appl., 2010, 46, (4), pp. 1509–1517 (doi: 10.1109/TIA.2010.2049974).
-
10)
-
M. Hanif ,
M. Basu ,
K. Gaughan
.
Understanding the operation of a Z-source inverter for photovoltaic application with a design example.
IET Power Electron.
,
278 -
287
-
11)
-
P. Palanivel ,
S.S. Dash
.
Analysis of THD and output voltage performance for cascaded multilevel inverter using carrier pulse width modulation techniques.
IET J. Power Electron.
,
8 ,
951 -
958
-
12)
-
K. Zhang ,
Y. Kang ,
J. Xiong ,
J. Chen
.
Direct repetitive control of SPWM inverter for UPS purpose.
IEEE Trans. Power. Electron.
,
3 ,
784 -
792
-
13)
-
7. Lazzarin, T.B., Barbi, I.: ‘DSP-based control for parallelism of three-phase voltage source inverter’, IEEE Trans. Ind. Inf., 2013, 9, (2), pp. 749–759 (doi: 10.1109/TII.2012.2223477).
-
14)
-
18. Figueres, E., Benavent, J.M., Garcera, G., et al: ‘A control circuit with load-current injection for single-phase power-factor-correction rectifiers’, IEEE Trans. Ind. Electron., 2007, 54, (3), pp. 1272–1281 (doi: 10.1109/TIE.2007.891987).
-
15)
-
D.M. Vilathgamuwa ,
A.A.D. Ranjith Perera ,
S.S. Choi
.
Voltage sag compensation with energy optimized dynamic voltage restorer.
IEEE Trans. Power Deliv.
,
3 ,
928 -
936
-
16)
-
10. Weiwei, L., Xinbo, R., Donghua, P., et al: ‘Full-feedforward schemes of grid voltages for a three-phase LCL-type grid-connected inverter’, IEEE Trans. Ind. Electron., 2013, 60, (6), pp. 2237–2250 (doi: 10.1109/TIE.2012.2193864).
-
17)
-
7. Khadkikar, V.: ‘Enhancing electric power quality using UPQC: a comprehensive overview’, IEEE Trans. Power Electron., 2012, 27, (5), pp. 2284–2297 (doi: 10.1109/TPEL.2011.2172001).
-
18)
-
W. Xuehua ,
R. Xinbo ,
L. Shangwei ,
C.K. Tse
.
Full feedforward of grid voltage for grid-connected inverter with LCL filter to suppress current distortion due to grid voltage harmonics.
IEEE Trans. Power Electron.
,
12 ,
3119 -
3127
-
19)
-
6. Lam, C.-S., Wong, M.-C., Han, Y.-D.: ‘Hysteresis current control of hybrid active power filters’, IET Power Electron., 2012, 5, (7), pp. 1175–1187 (doi: 10.1049/iet-pel.2011.0300).
-
20)
-
6. Balathandayuthapani, S., Edrington, C.S., Henry, S.D., Cao, J.: ‘Analysis and control of a photovoltaic system: application to a high-penetration case study’, IEEE Syst. J., 2012, 6, (2), pp. 213–219 (doi: 10.1109/JSYST.2011.2162889).
-
21)
-
21. Eirea, G., Sanders, S.R.: ‘Adaptive output current feed forward control in VR applications’, IEEE Trans. Power Electron., 2008, 23, (4), pp. 1880–1887 (doi: 10.1109/TPEL.2008.925199).
-
22)
-
I. Millan ,
J.M. Burdio ,
J. Acero ,
O. Lucia ,
S. Llorente
.
Series resonant inverter with selective harmonic operation applied to all-metal domestic induction heating.
IET Power Electron.
,
5 ,
587 -
592
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-pel.2014.0050
Related content
content/journals/10.1049/iet-pel.2014.0050
pub_keyword,iet_inspecKeyword,pub_concept
6
6