© The Institution of Engineering and Technology
This study proposes the application of a current controller based on the reduced order generalised integrator (ROGI) to control a three-phase three-wire shunt active power filter (SAPF). The ROGI-based controller has low computational burden and it is suitable for its implementation in low-cost digital signal processors (DSPs). This controller is also frequency adaptive. This allows it to maintain its high steady-state performance despite grid frequency variations. Unlike conventional high performance SAPFs this current controller does not require the computation of high quality current references (with low distortion and total harmonic distortion below that recommended by the IEEE Std 519-1992). Therefore most of the available computational power can be used for compensating the harmonics produced by the load.
References
-
-
1)
-
25. Rodríguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., Blaabjerg, F.: ‘Multiresonant frequency-locked loop for grid synchronization of power converters under distorted grid conditions’, IEEE Trans. Ind. Electron.2011, 58, (1), pp. 127–138 (doi: 10.1109/TIE.2010.2042420).
-
2)
-
25. Mikkili, S., Panda, A.K.: ‘Simulation and real-time implementation of shunt active filter id–iq control strategy for mitigation of harmonics with different fuzzy membership functions’, IET Power Electron., 2012, 5, (9), pp. 1856–1872 (doi: 10.1049/iet-pel.2012.0254).
-
3)
-
M. Odavic ,
V. Biagini ,
P. Zanchetta ,
M. Sumner ,
M. Degano
.
One-sample-period-ahead predictive current control for high-performance active shunt power filters.
IET Power Electron. Inst. Eng. Technol.
,
4 ,
414 -
423
-
4)
-
A. Garcia-Cerrada ,
O. Pinzon-Ardila ,
V. Feliu-Battle ,
P. Roncero-Sanchez ,
P. Garcia-Gonzalez
.
Application of a repetitive controller for a three-phase active power filter.
IEEE Trans. Power Electron.
,
1 ,
237 -
246
-
5)
-
33. Gomez Jorge, S., Busada, C., Solsona, J.: ‘Frequency adaptive current controller for three phase grid connected converters’, IEEE Trans. Ind. Electron., 2013, 60, (10), pp. 4169–4177 (doi: 10.1109/TIE.2012.2209617).
-
6)
-
21. Pigazo, A., Moreno, V.M., Estebanez, E.J.: ‘A recursive park transformation to improve the performance of synchronous reference frame controllers in shunt active power filters’, IEEE Trans. Power Electron., 2009, 24, (9), pp. 2065–2075 (doi: 10.1109/TPEL.2009.2025335).
-
7)
-
17. Tang, Y., Loh, P.C., Wang, P., et al: ‘Generalized design of high performance shunt active power filter with output LCL filter’, IEEE Trans. Ind. Electron., 2012, 59, (3), pp. 1443–1452 (doi: 10.1109/TIE.2011.2167117).
-
8)
-
4. Kedjar, B., Al-Haddad, K.: ‘Dsp-based implementation of an lqr with integral action for a three-phase three-wire shunt active power filter’, IEEE Trans. Ind. Electron., 2009, 56, (8), pp. 2821–2828 (doi: 10.1109/TIE.2008.2006027).
-
9)
-
9. Suresh, Y., Panda, A., Suresh, M.: ‘Real-time implementation of adaptive fuzzy hysteresis-band current control technique for shunt active power filter’, IET Power Electron., 2012, 5, (7), pp. 1188–1195 (doi: 10.1049/iet-pel.2011.0371).
-
10)
-
29. Rodriguez, P., Luna, A., Munoz-Aguilar, R., Etxeberria-Otadui, I., Teodorescu, R., Blaabjerg, F.: ‘A stationary reference frame grid synchronization system for three-phase grid-connected power converters under adverse grid conditions’, IEEE Trans. Power Electron., 2011, 27, (1), pp. 99–112 (doi: 10.1109/TPEL.2011.2159242).
-
11)
-
K. Martin
.
Complex signal processing is not complex.
IEEE Trans. Circuits Syst. I
,
9 ,
1823 -
1836
-
12)
-
5. de Araujo Ribeiro, R., de Azevedo, C., de Sousa, R.: ‘A robust adaptive control strategy of active power filters for power-factor correction, harmonic compensation, and balancing of nonlinear loads’, IEEE Trans. Power Electron., 2012, 27, (2), pp. 718–730 (doi: 10.1109/TPEL.2011.2161334).
-
13)
-
14. Gomez Jorge, S., Busada, C., Solsona, J.: ‘Frequency adaptive discrete filter for grid synchronization under distorted voltages’, IEEE Trans. Power Electron., 2012, 27, (8), pp. 3584–3594 (doi: 10.1109/TPEL.2012.2185517).
-
14)
-
8. Guo, X., Wu, W., Chen, Z.: ‘Multiple-complex coefficient-filter-based phase-locked loop and synchronization technique for three-phase grid-interfaced converters in distributed utility networks’, IEEE Trans. Ind. Electron., 2011, 58, (4), pp. 1194–1204 (doi: 10.1109/TIE.2010.2041738).
-
15)
-
15. Busada, C.A., Gomez-Jorge, S., Leon, A.E., Solsona, J.A.: ‘Current controller based on reduced order generalized integrators for distributed generation systems’, IEEE Trans. Ind. Electron., 2012, 59, (7), pp. 2898–2909 (doi: 10.1109/TIE.2011.2167892).
-
16)
-
17)
-
6. Tang, Y., Loh, P.C., Wang, P., Choo, F.H., Gao, F., Blaabjerg, F.: ‘Generalized design of high performance shunt active power filter with output lcl filter’, IEEE Trans. Ind. Electron., 2012, 59, (3), pp. 1443–1452 (doi: 10.1109/TIE.2011.2167117).
-
18)
-
19. Vaccaro, R.J.: ‘Digital control: a state-space approach’ (McGraw-Hill, Inc, 1995).
-
19)
-
10. Mikkili, S., Panda, A.: ‘Simulation and real-time implementation of shunt active filter id-iq control strategy for mitigation of harmonics with different fuzzy membership functions’, IET Power Electron., 2012, 5, (9), pp. 1856–1872 (doi: 10.1049/iet-pel.2012.0254).
-
20)
-
7. Rodríguez, P., Luna, A., Muñoz-Aguilar, R., Etxeberria-Otadui, I., Teodorescu, R., Blaabjerg, F.: ‘A stationary reference frame grid synchronization system for three-phase grid-connected power converters under adverse grid conditions’, IEEE Trans. Power Electron., 2012, 27, (1), pp. 99–112 (doi: 10.1109/TPEL.2011.2159242).
-
21)
-
8. Odavic, M., Biagini, V., Zanchetta, P., Sumner, M., Degano, M.: ‘One-sample-period-ahead predictive current control for high-performance active shunt power filters’, IET Power Electron., 2011, 4, (4), pp. 414–423 (doi: 10.1049/iet-pel.2010.0137).
-
22)
-
17. Martin, K.: ‘Complex signal processing is not complex’, IEEE Trans. Circuits Syst. I, Regul. Pap., 2004, 51, (9), pp. 1823–1836 (doi: 10.1109/TCSI.2004.834522).
-
23)
-
9. Suresh, Y., Panda, A., Suresh, M.: ‘Real-time implementation of adaptive fuzzy hysteresis-band current control technique for shunt active power filter’, IET Power Electron., 2012, 5, (7), pp. 1188–1195 (doi: 10.1049/iet-pel.2011.0371).
-
24)
-
25)
-
15. Busada, C.A., Gomez-Jorge, S., Leon, A.E., Solsona, J.A.: ‘Current controller based on reduced order generalized integrators for distributed generation systems’, IEEE Trans. Ind. Electron., 2012, 59, (7), pp. 2898–2909 (doi: 10.1109/TIE.2011.2167892).
-
26)
-
20. Bryson, A.E., Ho, Y.-C.: ‘Applied optimal control: optimization, estimation, and control’ (. John Wiley & Sons., 1975).
-
27)
-
13. Xiaoqiang, G., Weiyang, W., Zhe, C.: ‘Multiple-complex coefficient-filter-based phase-locked loop and synchronization technique for three-phase grid-interfaced converters in distributed utility networks’, IEEE Trans. Ind. Electron., 2011, 58, (4), pp. 1194–1204 (doi: 10.1109/TIE.2010.2041738).
-
28)
-
14. Gomez Jorge, S., Busada, C., Solsona, J.: ‘Frequency adaptive discrete filter for grid synchronization under distorted voltages’, IEEE Trans. Power Electron., 2012, 27, (8), pp. 3584–3594 (doi: 10.1109/TPEL.2012.2185517).
-
29)
-
16. Gomez Jorge, S., Busada, C., Solsona, J.: ‘Frequency-adaptive current controller for three-phase grid-connected converters’, IEEE Trans. Ind. Electron., 2013, 60, (10), pp. 4169–4177 (doi: 10.1109/TIE.2012.2209617).
-
30)
-
12. Rodriguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., Blaabjerg, F.: ‘Multiresonant frequency-locked loop for grid synchronization of power converters under distorted grid conditions’, IEEE Trans. Ind. Electron., 2011, 58, (1), pp. 127–138 (doi: 10.1109/TIE.2010.2042420).
-
31)
-
11. Teodorescu, R., Liserre, M., Rodríguez, P.: Grid converters for photovoltaic and wind power systems’ (, Wiley-IEEE., 2011).
-
32)
-
5. de Araujo Ribeiro, R., de Azevedo, C., de Sousa, R.: ‘A robust adaptive control strategy of active power filters for power-factor correction, harmonic compensation, and balancing of nonlinear loads’, IEEE Trans. Power Electron., 2012, 27, (2), pp. 718–730 (doi: 10.1109/TPEL.2011.2161334).
-
33)
-
3. Pigazo, A., Moreno, V., Estebanez, E.: ‘A recursive park transformation to improve the performance of synchronous reference frame controllers in shunt active power filters’, IEEE Trans. Power Electron., 2009, 24, (9), pp. 2065–2075 (doi: 10.1109/TPEL.2009.2025335).
-
34)
-
2. Garcia-Cerrada, A., Pinzon-Ardila, O., Feliu-Batlle, V., Roncero-Sanchez, P., Garcia-Gonzalez, P.: ‘Application of a repetitive controller for a three-phase active power filter’, IEEE Trans. Power Electron., 2007, 22, (1), pp. 237–246 (doi: 10.1109/TPEL.2006.886609).
-
35)
-
4. Kedjar, B., Al-Haddad, K.: ‘Dsp-based implementation of an lqr with integral action for a three-phase three-wire shunt active power filter’, IEEE Trans. Ind. Electron., 2009, 56, (8), pp. 2821–2828 (doi: 10.1109/TIE.2008.2006027).
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-pel.2013.0292
Related content
content/journals/10.1049/iet-pel.2013.0292
pub_keyword,iet_inspecKeyword,pub_concept
6
6