Application of let-through energy to back-up over-current protection on high-voltage feeders

Application of let-through energy to back-up over-current protection on high-voltage feeders

For access to this article, please select a purchase option:

Buy eFirst article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

Let-through energy (LTE) refers to the I 2 t or Joule energy that a conductor is exposed to during a fault on the feeder. This energy is influenced by the magnitude of the fault current and time it takes for the protection system to clear the fault. If the LTE exceeds the conductor thermal energy limit, the conductor will get damaged. This concept of LTE evaluation is applied to the inverse definite minimum time (IDMT) current based back-up protection elements on a multisource high-voltage feeder in a hypothetical and actual network. Another method to calculate the relay operating time for IDMT relays was developed based on an average disk speed of electromechanical over-current relay and the proportionality of its speed to the magnitude of the fault current. This method was incorporated into a software application to generate results. These results allow the user to evaluate the conductor LTE exposure, total fault time exposure, the effect of instantaneous fault clearing and the application of auto-reclose cycles. An energy-area evaluation was applied to quantify and evaluate small protection settings changes. The conclusion is that LTE analysis on back-up protection should be considered for high-voltage feeders to ensure that the conductors are protected.