Sub-synchronous oscillations caused by the control of LCC HVDC transmission line under the condition of open-loop modal coupling

Sub-synchronous oscillations caused by the control of LCC HVDC transmission line under the condition of open-loop modal coupling

For access to this article, please select a purchase option:

Buy eFirst article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

This study examines the sub-synchronous oscillations (SSOs) caused by the control of a line commutated converter high-voltage, direct current (LCC HVDC) transmission line in a power system with a doubly fed induction generator for the wind power generation. The examination is based on a closed-loop interconnected model consisted of an open-loop HVDC subsystem and an open-loop subsystem of power generation. The open-loop modal coupling is the modal condition that an SSO mode of the open-loop HVDC subsystem is close to an open-loop SSO mode of the power generation subsystem on the complex plane. Analysis in the study indicates that under the condition of open-loop modal coupling, the LCC HVDC line may induce strong dynamic interactions which degrade the damping of power system SSOs. An SSO index is derived to assess the degree of damping degradation of the SSOs, which can be used to identify the SSO instability risk brought about by the control of LCC HVDC transmission line. Hence, the mechanism of why the control of LCC HVDC transmission line may cause power system SSOs is revealed from the perspective of open-loop modal coupling. Study cases are presented to demonstrate and validate the analysis and conclusions made in the study.

http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2018.5892
Loading

Related content

content/journals/10.1049/iet-gtd.2018.5892
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address