access icon free Study on artificial multi-stress ageing characteristics of composite insulators

In recent years, abnormal heating of composite insulators has become a serious problem, especially in the coastal areas of southern China. In this paper, an improved multi-stress aging test for composite insulators was proposed based on the environment of the coastal areas in southern China, and 5000 h aging test was carried out. The test results showed that the wet flash-over voltage decreased linearly, while the hydrophobicity of the shed showed a nonlinear aging characteristics, whose change rate increased gradually. The multi-stress aging condition had little influence on shed hardness for the change of the shed hardness remained within 1%. The aged composite insulator showed significant temperature rise and the temperature rise concentrated on the high voltage end at high humidity, while it showed little temperature rise at low humidity. The dielectric loss of silicone rubber after moisture absorption was tested. It could effectively reflect the moisture absorption characteristics and the dielectric properties of silicone rubber after moisture absorption, and was closely related to the wet flash-over voltage and temperature rise of the composite insulator. The dielectric loss of silicone rubber after moisture absorption could be used as a new method to evaluate the operating state of composite insulators.

Inspec keywords: flashover; hydrophobicity; composite insulators; ageing; dielectric losses; silicone rubber; absorption

Other keywords: dielectric properties; artificial multistress ageing characteristics; composite insulators; environmental characteristics; moisture absorption characteristics; southern China; nonlinear ageing characteristic; high-voltage end-fitting; coastal areas; hydrophobicity; dielectric loss; abnormal heating; wet flash-over voltage; temperature rise; long-term performance evaluation methods; improved multistress ageing test; alternating electric field; silicone rubber

Subjects: Power line supports, insulators and connectors; Organic insulation; Dielectric breakdown and discharges

References

    1. 1)
      • 12. Sundararajan, R., Soundarajan, E., Mohammed, A., et al: ‘Multistress accelerated ageing of polymer housed surge arresters under simulated coastal Florida conditions’, IEEE Trans. Dielectr. Electr. Insul., 2006, 13, (1), pp. 211226.
    2. 2)
      • 24. IEC 61109: ‘Composite insulators for a.c. overhead lines with nominal voltage greater than 1000V – definitions, test procedures and acceptance criteria’, 2008.
    3. 3)
      • 20. Zhang, F., Song, L., Li, R.: ‘Evaluation method of defect and fracture reason for composite insulator’, High Volt. Eng., 2012, 38, (11), pp. 30933100(in Chinese).
    4. 4)
      • 16. Li, S., Liang, X., Gao, Y., et al: ‘A modified 5000 h test procedure for silicone rubber insulator based on contamination and hydrophobicity change simulation’, IEEE Trans. Dielectr. Electr. Insul., 2017, 24, (3), pp. 18181828.
    5. 5)
      • 3. Liang, X., Wang, S., Fan, J., et al: ‘Development of composite insulators in China’, IEEE Trans. Dielectr. Electr. Insul., 1999, 6, (5), pp. 586594.
    6. 6)
      • 25. IEC 60060-1: ‘High-voltage test techniques – part 1: general definitions and test requirements’, 2010.
    7. 7)
      • 17. Cheng, Y., Li, C., Chen, M., et al: ‘Research on the abnormal heat of composite insulator in high voltage transmission power line’, Power Syst. Technol., 2005, 29, (5), pp. 5760(in Chinese).
    8. 8)
      • 8. Li, Q., Su, Z.: ‘5000 h artificial accelerating ageing test of HVDC composite insulator’, Power Syst. Technol., 2006, 30, (12), pp. 6468(in Chinese).
    9. 9)
      • 22. Tu, Y., Gong, B., Yuan, Z., et al: ‘Moisture induced local heating of overhead line composite insulators’, IEEE Trans. Dielectr. Electr. Insul., 2017, 24, (1), pp. 483489.
    10. 10)
      • 29. Wang, X., Sun, X., Liu, Q., et al: ‘Research development of ageing models of insulation materials based on space charge effect’, High Volt. Eng., 2016, 42, (3), pp. 861867(in Chinese).
    11. 11)
      • 2. Cui, J., Su, Z., Yi, H.: ‘The application and its prospect of silicone rubber composite insulators in China’, Electr. Power, 1999, 32, (1), pp. 3841(in Chinese).
    12. 12)
      • 27. GB/T 19519: ‘Insulators for overhead lines – composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1000 V – definitions, test methods and acceptance criteria’, 2014.
    13. 13)
      • 6. Hackam, R.: ‘Outdoor HV composite polymeric insulators’, IEEE Trans. Dielectr. Electr. Insul., 1999, 6, (5), pp. 557585.
    14. 14)
      • 18. Morshuis, P.H.F.: ‘Degradation of solid dielectrics due to internal partial discharge: some thoughts on progress made and where to go now’, IEEE Trans. Dielectr. Electr. Insul., 2005, 12, (5), pp. 905913.
    15. 15)
      • 5. CIGRE TF 33.04.07: ‘Natural and artificial ageing and pollution test of polymeric insulators’ (CIGRE brochure 142, Paris, France, 1999).
    16. 16)
      • 9. Liang, X., Zhang, Y., Yin, Y., et al: ‘5000 h multi-stress test procedure for silicone rubber composite insulators and its applications in long term performance evaluation’, High Volt. Eng., 2012, 38, (10), pp. 24922498(in Chinese).
    17. 17)
      • 13. Lee, J.B., Song, I.K., Kim, J.Y., et al: ‘Ageing characteristics of polymer lightning arrester by multi-stress accelerated ageing test’. IEEE Int. Conf. Solid Dielectrics, Toulouse, France, 5–9 July 2004, pp. 248253.
    18. 18)
      • 1. Guan, Z., Liu, Y., Zhou, Y., et al: ‘Insulator and insulation of power transmission and transformation equipment’ (Tsinghua University Press, Beijing, 2006, 1st edn.), pp. 6567(in Chinese).
    19. 19)
      • 21. Wang, C., Li, T., Tu, Y., et al: ‘Heating phenomenon in unclean composite insulators’, Eng. Fail. Anal., 2016, 65, pp. 4856.
    20. 20)
      • 11. Garcia, R.W.S., Torres, M.S., Silva, F.R., et al: ‘Natural and accelerated ageing of composite insulators’. IEEE Int. Symp. Electrical Insulation, Arlington, VA, USA, 7–10 June 1998, pp. 329333.
    21. 21)
      • 26. GB/T 1001.2: ‘Insulators for overhead lines with a nominal voltage above 1000 V – part 2: insulator strings and insulator sets for a. c. Systems – definitions, test methods and acceptance criteria’, 2010.
    22. 22)
      • 7. Yin, Y., Liang, X., Zhou, Y., et al: ‘Analysis on failures of silicone rubber composite insulators in tracking wheel test’, Power Syst. Technol., 2004, 28, (19), pp. 6871(in Chinese).
    23. 23)
      • 19. Da Costa, E.G., Ferreir, T.V., Neri, M.G.G., et al: ‘Characterization of polymeric insulators using thermal and UV imaging under laboratory conditions’, IEEE Trans. Dielectr. Electr. Insul., 2009, 16, (4), pp. 985992.
    24. 24)
      • 28. GB/T 531: ‘Rubber – determination of indentation hardness by means of pocket hardness meters’, 1999.
    25. 25)
      • 10. Schneider, H.M., Guidi, W.W., Burnham, J.T., et al: ‘Accelerated ageing and flashover tests on 138 kV nonceramic line post insulators’, IEEE Trans. Power Deliv., 1993, 8, (1), pp. 325336.
    26. 26)
      • 23. Tu, Y., Gong, B., Wang, C., et al: ‘Effect of moisture on temperature rise of composite insulators operating in power system’, IEEE Trans. Dielectr. Electr. Insul., 2015, 22, (4), pp. 22072213.
    27. 27)
      • 30. Tokoro, T., Hackam, R.: ‘Loss and recovery of hydrophobicity and surface energy of HTV silicone rubber’, IEEE Trans. Dielectr. Electr. Insul., 2001, 8, (6), pp. 10881097.
    28. 28)
      • 15. IEC 62217: ‘Polymeric insulators for indoor and outdoor use with a nominal voltage greater than 1000V – general definitions, test methods and acceptance criteria’, 2005.
    29. 29)
      • 14. IEC 1109: ‘Composite insulators for a.c. overhead lines with a nominal voltage greater than 1000 V – definitions, test procedures and acceptance criteria’, 1992.
    30. 30)
      • 4. Liang, X., Gao, Y., Wang, J., et al: ‘Rapid development of silicone rubber composite insulator in China’, High Volt. Eng., 2016, 42, (9), pp. 28882896(in Chinese).
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2018.5270
Loading

Related content

content/journals/10.1049/iet-gtd.2018.5270
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading