Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

access icon free Non-linear LS-SVM with RBF-kernel-based approach for AGC of multi-area energy systems

Support vector machine (SVM) is very efficacious in pattern recognition and function estimation problems. However, its application to design efficient automatic generation control (AGC) scheme has not been investigated till date by the researchers and power engineers worldwide. Hence, in this study an early attempt has been made to present a combined design of optimal control and optimisation problem of least-squares SVM (LS-SVM)-based AGC of multi-area energy systems. The radial basis function (RBF) kernel is used to train the LS-SVM. To validate the efficacy of the approach, the proposed control method is implemented on various 2-area system models such as non-reheat thermal, reheat thermal and hydro-thermal energy systems. The trained LS-SVM RBF-kernel-based AGC is realised with 1% load perturbation in one of the control area and the obtained results are compared with multi-layer perceptron artificial neural network and the conventional integral based controller in order to show the supremacy of the proposed control design. Furthermore, the performance of the AGC design is examined considering the system non-linearities such as governor dead-band and generation rate constraint.

References

    1. 1)
      • 6. Elgerd, O.I., Fosha, C.: ‘Optimum megawatt frequency control of multi-area electric energy systems’, IEEE Trans. Power Appar. Syst., 1970, PAS-89, (4), pp. 556563.
    2. 2)
      • 15. Demiroren, A., Sengor, N.S., Zeynelgil, H.L.: ‘Automatic generation control for power system with SMES by using neural network controller’, Electr. Power Comput. Syst., 2003, 31, (1), pp. 125.
    3. 3)
      • 4. Abdelaziz, A.Y., Ali, E.S.: ‘Cuckoo search algorithm based load frequency controller design for nonlinear interconnected power system’, Int. J. Electron. Power Energy Syst., 2015, 73, pp. 632643.
    4. 4)
      • 14. Demiroren, A., Sengor, N.S., Zeynelgil, H.L.: ‘Automatic generation control by using ANN technique’, Electr. Power Comput. Syst., 2001, 29, (10), pp. 883896.
    5. 5)
      • 5. Arya, Y., Kumar, N., Ibraheem, : ‘AGC of a two-area multi-source power system interconnected via AC/DC parallel links under restructured power environment’, Optim. Control Appl. Methods, 2016, 37, (4), pp. 590607.
    6. 6)
      • 19. Vapnik, V.: ‘Statistical learning theory’ (John Wiley, New York, NY, 1998).
    7. 7)
      • 13. Arya, Y., Kumar, N.: ‘AGC of a multi-area multi-source hydrothermal power system interconnected via AC/DC parallel links under deregulated environment’, Int. J. Electron. Power Energy Syst., 2016, 75, pp. 127138.
    8. 8)
      • 2. Sharma, G., Nasiruddin, I., Niazi, K.R., et al: ‘Adaptive fuzzy critic based control design for AGC of power system connected via AC/DC tie-lines’, IET. Gener. Transm. Distrib., 2017, 11, (2), pp. 560569.
    9. 9)
      • 1. Sharma, G., Nasiruddin, I., Niazi, K.R., et al: ‘Robust automatic generation control regulators for a two-area power system interconnected via AC/DC tie-lines considering new structures of matrix Q’, IET. Gener. Transm. Distrib., 2016, 10, (14), pp. 35703579.
    10. 10)
      • 18. Sharma, G., Niazi, K. R., Ibraheem, : ‘Recurrent ANN based AGC of a two-area power system with DFIG based wind turbines considering asynchronous tie-lines’. IEEE Int. Conf. Advances in Engineering & Technology Research (ICAETR-2014), Unnao, India, August 2014, pp. 15.
    11. 11)
      • 12. Ibraheem, Niazi, K.R., Sharma, G.: ‘Study on dynamic participation of wind turbines in AGC of power system’, Electr. Power Compon. Syst., 2014, 43, (1), pp. 4455.
    12. 12)
      • 21. Sharma, G., Niazi, K.R., Ibraheem, , et al: ‘LS-SVM based AGC of power system with dynamic participation from DFIG based wind turbines’. Third Renewable Power Generation Conf. (RPG), Naples, Italy, 2014, 24–25 September.
    13. 13)
      • 10. Ibraheem, Kumar, P.: ‘Current status of the Indian power system and dynamic performance enhancement of hydro power systems with asynchronous tie lines’, Electr. Power Comput. Syst., 2003, 31, (7), pp. 605626.
    14. 14)
      • 20. Boolchandani, D., Ahmed, A., Sahula, V.: ‘Efficient kernel functions for support vector machine regression model for analog circuits performance evaluation’, Analog. Integr. Circuits Signal Process., 2011, 66, (1), pp. 117128.
    15. 15)
      • 8. Ibraheem, Kumar, P., Kothari, D.P.: ‘Recent philosophies of automatic generation control strategies in power systems’, IEEE Trans. Power Syst., 2005, 20, (1), pp. 346357.
    16. 16)
      • 9. Fosha, C. E., Elgerd, O. I.: ‘The megawatt frequency control problem: a new approach via optimal control theory’, IEEE Trans. Power Apparat. Syst., 1970, PAS-89, (4), pp. 563577.
    17. 17)
      • 11. Ibraheem, Kumar, P., Hasan, N., et al: ‘Optimal automatic generation control of interconnected power system with asynchronous tie-lines under deregulated environment’, Electr. Power Comput. Syst., 2012, 40, (10), pp. 12081228.
    18. 18)
      • 3. Yousef, H.: ‘Adaptive fuzzy logic load frequency control of multi-area power system’, Int. J. Electron. Power Energy Syst., 2015, 68, pp. 384395.
    19. 19)
      • 16. Ahamed, T.P.I., Rao, P.S.N., Sastry, P.S.: ‘A reinforcement learning approach to automatic generation control’, Electr. Power Syst. Res., 2002, 63, (1), pp. 926.
    20. 20)
      • 17. Ahamed, T.P.I., Rao, P.S.N., Sastry, P.S.: ‘Reinforcement learning controllers for automatic generation control in power systems having reheat units with GRC and dead-band’, Int. J. Power Energy Syst., 2006, 26, (2), pp. 137146.
    21. 21)
      • 7. Willems, J.L.: ‘Sensitivity analysis of the optimum performance of conventional load frequency control’, IEEE Trans. Power Appar. Syst., 1974, PAS-93, (5), pp. 12871291.
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2017.1402
Loading

Related content

content/journals/10.1049/iet-gtd.2017.1402
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address