Efficient method for the real-time contingency analysis of meshed HVDC power grids fed by VSC stations

Efficient method for the real-time contingency analysis of meshed HVDC power grids fed by VSC stations

For access to this article, please select a purchase option:

Buy eFirst article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
— Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

An efficient method for the real-time contingency analysis of meshed high-voltage direct current (HVDC) power grids fed by voltage source converter (VSC) stations is introduced here. A linearised AC/DC grid model is initially determined considering the control strategies of the various VSC units. This lays the foundations for the determination of linear sensitivity factors with which the contingency analysis is carried out to evaluate the real-time N−1 criterion in AC/DC grids, as demanded by system control centres. Distribution and power-injection factors are subsequently derived for efficiently assessing the impact of AC/DC transmission line outages and load/generator disconnections on the HVDC grid. Conversion factors are also derived to estimate the impact of the loss of VSC stations on the AC/DC network, this being another inherent contribution of this work. The efficiency and validity of this timely approach, which finds practical applicability to the real-time operation of HVDC power grids, is confirmed using a meshed DC network fed by three VSC stations. The disconnection of AC and DC transmission lines, generators, and VSC stations are dynamically simulated using Simulink and their post-disturbance steady-state conditions are compared against those computed by the introduced method where it is confirmed that both solutions concur very well with each other.

http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2017.1104
Loading

Related content

content/journals/10.1049/iet-gtd.2017.1104
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address