© The Institution of Engineering and Technology
Partial discharge (PD) is an early manifestation of insulation fault that occurs in electrical equipment, which holds rich feature information used to insulation assessment. In this study, step voltage method was applied to investigate the PD development process of typical protrusion defects in gas-insulated switchgear. Nine features were extracted to represent the deterioration degree of internal insulation. Fuzzy C means clustering was applied to solve the state centres. PD severity was divided into four states based on the PD developing process, and the harmfulness of each state was illustrated. Finally, adaptive objective weight technology based on the theory of maximising deviation was adopted, and two-level fuzzy comprehensive evaluation (TL-FCE) model was established to address the problem of the weight allocation of different features on the evaluation result. The experimental test has been conducted to test the validity and effectiveness of the model. It is proved that TL-FCE owns good performance to assess PD severity, and it is more suitable to handle fuzzy boundary problems than support vector machine.
References
-
-
1)
-
12. Chen, W.G., Xie, B., Long, Z.Z., et al: ‘Stage identification in air-gap discharge of oil-impregnated paper insulation’, Proc. CSEE, 2015, 35, (0), pp. 1–8.
-
2)
-
8. Qi, B.C., Li, R., Geng, B.B., et al: ‘Severity diagnosis and assessment of the partial discharge provoked by high-voltage electrode defect on GIS insulator surface’, IEEE Trans. Power Deliv., 2011, 26, (4), pp. 2363–2369 (doi: 10.1109/TPWRD.2011.2162753).
-
3)
-
24. Hunter, J.A., Hao, L., Lewin, P.L., et al: ‘Comparison of two partial discharge classification methods’, Conf. Record of the 2010 IEEE Int. Symp. on Electrical Insulation (ISEI), San Diego, 2010, pp. 1–5.
-
4)
-
16. Kang, S.W., Peng, J.C., He, Y.Q.: ‘Comprehensive evaluation of power quality based on the integration of fuzzy analytic hierarchy process with multi-objective decision-making’, Power Syst. Technol., 2009, 33, (19), pp. 113–118.
-
5)
-
6. Dreisbusch, V., Kranz Schnettler, H.G.A.: ‘Determination of a failure probability prognosis based on PD – diagnostics in GIS’, IEEE Trans. Dielectr. Electr. Insul., 2008, 15, (6), pp. 1707–1714 (doi: 10.1109/TDEI.2008.4712675).
-
6)
-
1. Van Schaik, N., Czaszejko, T.: ‘Conditions of discharge-free operation of XLPE insulated power cable systems’, IEEE Trans. Dielectr. Electr. Insul., 2008, 15, (4), pp. 1120–1130 (doi: 10.1109/TDEI.2008.4591235).
-
7)
-
20. Ohtsuka, S., Teshima, T., Matsumoto, S., et al: ‘Relationship between PD-induced electromagnetic wave measured with UHF method and charge quantity obtained by PD current waveform in model GIS’. IEEE Electrical Insulation and Dielectric Phenomena Conf., Kansas City, 2006, pp. 615–618.
-
8)
-
2. Najafipour, A., Babaee, A., Shahrtash, S.M.: ‘Comparing the trustworthiness of signal-to-noise ratio and peak signal-to-noise ratio in processing noise partial discharge signals’, IET Sci. Meas. Technol., 2013, 7, (2), pp. 112–118 (doi: 10.1049/iet-smt.2012.0113).
-
9)
-
18. Dong, Y.L., Tang, J., Zeng, F.P.: ‘Features extraction and mechanism analysis of partial discharge development under protrusion defect’, J. Electr. Eng. Technol., 2015, 10, (1), pp. 344–354 (doi: 10.5370/JEET.2015.10.1.344).
-
10)
-
5. Strachan, S.M., Rudd, S., McArthur, S.D.J., et al: ‘Knowledge-based diagnosis of partial discharges in power transformers’, IEEE Trans. Dielectr. Electr. Insul., 2008, 15, (1), pp. 259–268 (doi: 10.1109/T-DEI.2008.4446759).
-
11)
-
23. Xie, L.J., Li, L., Cheng, Y., et al: ‘A fault diagnosis method of power transformers by integrated set pair analysis and association rules’, Proc. CSEE, 2015, 35, (2), pp. 277–286.
-
12)
-
4. Li, J., Riao, R.J., Grzybowski, S., et al: ‘Oil-paper aging evaluation by fuzzy clustering and factor analysis to statistical parameters of partial discharges’, IEEE Trans. Dielectr. Electr. Insul., 2010, 17, (3), pp. 756–763 (doi: 10.1109/TDEI.2010.5492248).
-
13)
-
19. IEC 60270-2000.: , 2000.
-
14)
-
21. Zadeh, L.A.: ‘Fuzzy sets’, Inf. Control, 1965, 8, (3), pp. 338–353 (doi: 10.1016/S0019-9958(65)90241-X).
-
15)
-
7. Wang, C.X., Tang, Z.G., Chang, W.Z., et al: ‘Experimental study on development characteristics of point discharge in GIS’, Power Syst. Technol., 2011, 35, (11), pp. 157–162.
-
16)
-
15. Xiao, X.Y., Ma, C., Yang, H.G., et al: ‘Failure probability analysis of sensitive equipment due to voltage sags using fuzzy-random assessment method’, IEEE Trans. Power Deliv., 2010, 25, (4), pp. 2970–2975 (doi: 10.1109/TPWRD.2009.2036263).
-
17)
-
3. Tang, J., Zhou, Q., Tang, M., et al: ‘Study on mathematical model for VHF partial discharge of typical insulated defects in GIS’, IEEE Trans. Dielectr. Electr. Insul., 2007, 14, (1), pp. 30–38 (doi: 10.1109/TDEI.2007.302869).
-
18)
-
11. Tao, J.G.: ‘Study on partial discharge identification and harmfulness assessment for gas insulated switchgear’. , Chongqing University, 2013.
-
19)
-
13. Cortes, C., Vapnik, V.: ‘Support-vector networks’, Mach. Learn., 1995, 20, (3), pp. 273–297.
-
20)
-
10. Liao, R.J., Yang, L.J., Li, J., et al: ‘Aging condition assessment of transformer oil-paper insulation model based on partial discharge analysis’, IEEE Trans. Dielectr. Electr. Insul., 2011, 18, (1), pp. 303–311 (doi: 10.1109/TDEI.2011.5704522).
-
21)
-
9. Qi, B., Li, C.R., Hao, Z., et al: ‘Surface discharge initiated by immobilized metal particles attach to gas insulated substation insulators: process and feature’, IEEE Trans. Dielectr. Electr. Insul., 2011, 183, (3), pp. 792–800 (doi: 10.1109/TDEI.2011.5931067).
-
22)
-
14. Liao, R.J., Zheng, H.B., Grzybowski, S., et al: ‘An integrated decision-making model for condition assessment of power transformers using fuzzy approach and evidential reasoning’, IEEE Trans. Power Deliv., 2011, 26, (2), pp. 1111–1118 (doi: 10.1109/TPWRD.2010.2096482).
-
23)
-
4. Lin, P.-C., Gu, J.-C., Yang, M.-T.: ‘Adaptive neuro-fuzzy inference system for monitoring the surface condition of polymeric insulators using harmonic content’, IET Gener. Transm. Distrib., 2014, 8, (7), pp. 1244–1253 (doi: 10.1049/iet-gtd.2013.0124).
-
24)
-
17. Zuo, X., Zhang, H.L., Deng, Q.J., et al: ‘Safety assessment of control system based on fuzzy comprehensive evaluation’. 2012 Ninth Int. Conf. on Fuzzy Systems and Knowledge Discovery, Sichuan, 2012, pp. 586–591.