access icon free Circuit breaker condition assessment through a fuzzy-probabilistic analysis of actuating coil's current

Circuit breaker (CB) is a component providing significant electrical protection for power transmission and distribution systems. Hence, an effective condition monitoring system for the CBs is of imminent importance. This study presents a fuzzy-probabilistic-based condition assessment algorithm to assess the CB operation performance by monitoring its trip/close coil current (C.C.), and suggests a simple yet effective condition assessment tool. The C.C. patterns are acquired by measurements carried out on 60 CBs (72.5 kV, SF6) under faulty and normal conditions. To intelligently assess the CB's operating state (i.e. normal, alarm and emergency), in terms of its reliability, the optimum C.C. features with minimum interdependence were obtained. Furthermore, a fuzzy-probabilistic method is proposed based on the results of the statistical analyses of the features. The feasibility and applicability of the proposed method in CB condition assessment is verified against the experimental measured data.

References

    1. 1)
      • 13. Huang, X., Xia, H.: ‘Design of an on-line monitoring system of mechanical characteristics of high voltage circuit breakers’. Proc. of Int. Conf. Electronics, Communications and Control, 2011, pp. 36463649.
    2. 2)
      • 10. CIGRE Working Group 13.06.: ‘Final report of the second international enquiry on high voltage circuit breaker failures and defects in service’. Paris, September 1994.
    3. 3)
    4. 4)
      • 4. Garzon, R.D.: ‘High voltage circuit breakers: design and applications’ (Marcel Dekker, New York, 2002, 2nd edn.).
    5. 5)
    6. 6)
    7. 7)
    8. 8)
    9. 9)
      • 9. Knezev, M., Djekic, Z., Kezunovic, M.: ‘Automated circuit breaker monitoring’, Proc. of Int. Conf. Power Engineering Society General Meeting, 2007, pp. 2428.
    10. 10)
      • 14. Johal, H., Mousavi, M.J.: ‘Coil current analysis method for predictive maintenance of circuit breakers’. Proc. of Int. Conf. Transmission and Distribution Conf. and Exposition, 2008, pp. 2124.
    11. 11)
    12. 12)
    13. 13)
    14. 14)
      • 16. Sugimoto, T., Watanabe, T., Iwamoto, I.: ‘New maintenance method of circuit breaker driving by DC solenoid making use of the closing current waveform measurement’. Proc. of Int. Conf. Transmission and Distribution, 2002, pp. 788791.
    15. 15)
      • 18. Watson, R.: ‘Diagnostic technique facilitates timing and condition monitoring of circuit breakers’. Proc. of Int. Conf. Engineering Asset Management, London, UK, October 2000.
    16. 16)
      • 3. Flurscheim, H.: ‘Power Circuit Breaker Theory and Design’ Inspec/Iee, 1982.
    17. 17)
      • 17. Hu, X., Chao, L.: ‘Research on the condition parameter tester of high voltage circuit breakers’. Proc. of Int. Conf. Industrial Electronics and Applications, 2008, pp. 23892393.
    18. 18)
      • 21. Zimmermann, H.J.: ‘Fuzzy set theory and its applications’ (Kluwer Academic Press, 1991).
    19. 19)
      • 19. McCabe, A.K., Woodward, R.C., Provanzana, J.H., et al: ‘Condition monitoring on high voltage circuit-breakers: development methods and tests’. Proc. of Int. Conf. Large High Voltage Electric Systems, 1994, pp. 1323.
    20. 20)
      • 15. Peilei, R., Huang, J., Hu, X., et al: ‘Testing of circuit breakers using coil current characteristics analysis’. Proc. of Int. Conf. Control and Automation, 2009, pp. 185189.
    21. 21)
      • 20. Andrusca, M., Adam, M., Baraboi, A., et al: ‘Using fuzzy logic for diagnosis of technical condition of power circuit breakers’. Proc. of IEEE Int. Conf. Electrical and Power Engineering (EPE), 2014, pp. 268273.