Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

access icon free Voltage sag source location technology based on corresponding sequence components

Determining the relative region where voltage sags originates is useful to identify the responsible party causing the power quality problem and monitor system or equipment operating condition. As different kinds of voltage sag will cause different sequence components to change according to the neutral point operation mode in the distribution system, a modified incremental impedance-based method for determining voltage sag source (VSS) location is proposed in this study. This study starts with the VSS direction theory based on incremental impedance, and derives location criteria for different types of VSSs according to the neutral point operation mode of the Chinese distribution network. The VSS location strategy is finally accomplished through the analyses of voltage sag's capacity for passing through the service transformer and the impact of system transient on incremental impedance calculation. The method locates various VSSs based on existing PQ measure points and has clear physics concept. Theoretical analysis, simulation and lab experiments have verified its effectiveness.

References

    1. 1)
      • 8. Parsons, A.C., et al: ‘A direction finder for power quality disturbances based upon disturbance power and energy’. Proc. Eighth Int. Conf. on Harmonics and Quality of Power Proc., 1998, 1998, vol. 2.
    2. 2)
    3. 3)
    4. 4)
    5. 5)
    6. 6)
      • 19. Ahn, S.J., Won, D.J., Chung, I.Y., Moon, S.I.: ‘Determination of the relative location of voltage sag source according to event cause’. IEEE Power Engineering Society General Meeting, 2004, 2004.
    7. 7)
      • 5. Tao, S., Xiao, X., Liu, X.: ‘Study on distribution reliability considering voltage sags and acceptable indices’, Proc. Chin. Soc. Electr. Eng., 2005, 25, (21), pp. 6369.
    8. 8)
    9. 9)
      • 1. IEEE Std. 1159-1995: ‘Recommended practice for monitoring electric power quality’, 1995.
    10. 10)
      • 23. Tang, L., Lamoree, J., McGranaghan, M., Mehta, H.: ‘Distribution system voltage sags: interaction with motor and drive loads’. Proc. 1994 IEEE Power Engineering Society Transmission and Distribution Conf., 1994, 1994.
    11. 11)
    12. 12)
    13. 13)
    14. 14)
      • 16. Zhu, K., Xu, W.-Y.: ‘Faulty line detection based on incremental impedance theory’, Electr. Power Autom. Equip., 2007, 11, pp. 003.
    15. 15)
      • 11. Li, C., Tayjasanant, T., Xu, W.: ‘A method for voltage sag source detection by investigating slope of the system trajectory’, Proc. Ins. Elect. Eng., 2003, 150, (3), pp. 367372.
    16. 16)
      • 14. Mohammad, H.M., Younes, M., Mina, H.T.: ‘A novel method to locate the voltage sag source: a case study in the Brazilian power network (Mato Grosso)’, Przeglad Elektotechniczy (Electr. Rev.), 2013, 88, (3b), pp. 112112.
    17. 17)
    18. 18)
      • 4. Lei, G., Gu, W., Yuan, X.: ‘A voltage sag index considering compatibility between system and sensitive equipment’, Diangong Jishu Xuebao (Transactions of China Electrotechnical Society), 2010, 25, (12), pp. 132138.
    19. 19)
      • 7. Kazemi, A., Mohamed, A., Shareef, H., Zayandehroodi, H.: ‘Review of voltage sag source identification methods for power quality diagnosis’, Przeglad Elektotechniczy (Electr. Rev.), 2013, 89, (8), pp. 100106.
    20. 20)
    21. 21)
    22. 22)
      • 6. Leborgne, R.C., Karlsson, D., Daalder, J.: ‘Voltage sag source location methods performance under symmetrical and asymmetrical fault conditions’. Transmission & Distribution Conf. and Exposition: Latin America, TDC'06, 2006, pp. 16. DOI: 10.1109/TDCLA.2006.311546.
    23. 23)
      • 3. Kamble, S., Thorat, C.: ‘A new algorithm for voltage sag detection’. Int. Conf. on Advances in Engineering, Science and Management (ICAESM), 2012, 2012.
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2014.0772
Loading

Related content

content/journals/10.1049/iet-gtd.2014.0772
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field