Effects of air pressure and humidity on the corona onset voltage of bundle conductors

Access Full Text

Effects of air pressure and humidity on the corona onset voltage of bundle conductors

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

On the condition of adjusting air pressure from 58.7 to 98.7 kPa and air humidity from 5 to 17.3 g/m3 in the multifunctional artificial chamber, experiments on AC corona performance of scaled models of three kinds of bundle conductors are conducted and the mathematical model of corona discharge is proposed to calculate the corona onset voltages. Results indicate that the corona onset voltage of bundle conductors will decrease obviously with the decrease of air pressure, but the effect of air pressure on the corona onset voltage will decline with the increase of absolute humidity. When absolute humidity rises from 5 to 15 g/m3, the corona onset voltage increases slowly. Furthermore, the lower air pressure is, the more obvious effect of absolute humidity on the corona onset voltage is. Yet, the corona onset voltage drops remarkably when absolute humidity reaches 17.3 g/m3, owing to the condensation, which distorts the surface electric field, on the surface of conductors under high-humidity condition. In light of the condensation effect, the mathematical model of corona discharge is improved, which helps yield agreement between the measured results and the calculated results. Moreover, formulas for predicting corona onset voltages under various bundle configurations, air pressure and air humidity are also obtained. Calculated results from these formulas along with from mathematical models are compared with the measured results.

Inspec keywords: overhead line conductors; atmospheric humidity; electric fields; corona; atmospheric pressure

Other keywords: pressure 58.7 kPa to 98.7 kPa; corona discharge; AC corona performance; air humidity effects; surface electric field; multifunctional artificial chamber; absolute humidity; bundle conductor; corona onset voltage; air pressure effects

Subjects: Gaseous insulation, breakdown and discharges; Electric and magnetic fields; Overhead power lines

References

    1. 1)
      • Calva, P., Espino, C.: `Effect of the humidity in the ionic mobility in reduced air-density', Conf. on Electrical Insulation and Discharge Phenomena, October 1998, Atlanta, USA, 2, p. 508–511.
    2. 2)
      • GB/T 775.2–2003: ‘Test method for insulators – part 2: electrical test methods’, 2003.
    3. 3)
      • Q. Wang , L. Zhang , Z. Li . Influence of humidity on conductor corona onset voltage. Electr. Power Constr. , 8 , 38 - 41
    4. 4)
    5. 5)
      • X. Bian , J. Hui , H. Huang , L. Wang , Z. Guan , Y. Chen . Effects of air pressure and humidity on the characteristics of negative DC corona. Proc. CSEE , 4 , 118 - 124
    6. 6)
    7. 7)
    8. 8)
    9. 9)
      • IEC 60060–1 ed2.0: ‘High-voltage test techniques – part 1: general definitions and test requirements’, 1989.
    10. 10)
    11. 11)
    12. 12)
      • Q. Fei , D. Yue , G. Wu , B. Wan . The influence of the surface free engergy on the performance of air Collers. J. Dalian Marit. Univ. , 4 , 92 - 95
    13. 13)
      • GB/T 2317.2–2000: ‘Corona and RIV tests for electric power fittings’, 2000.
    14. 14)
    15. 15)
      • Y. Liu , J. Li , B. Li . Effect of air density and humidity on conductor corona performances. Power Syst. Technol. , 4 , 46 - 50
    16. 16)
      • L. Shu , X. Lai , D. Yu . Influence of atmospheric pressure on dc positive corona discharge in icicle to iced plate electrode system. Proc. CSEE , 7 , 116 - 120