© The Institution of Engineering and Technology
On the condition of adjusting air pressure from 58.7 to 98.7 kPa and air humidity from 5 to 17.3 g/m3 in the multifunctional artificial chamber, experiments on AC corona performance of scaled models of three kinds of bundle conductors are conducted and the mathematical model of corona discharge is proposed to calculate the corona onset voltages. Results indicate that the corona onset voltage of bundle conductors will decrease obviously with the decrease of air pressure, but the effect of air pressure on the corona onset voltage will decline with the increase of absolute humidity. When absolute humidity rises from 5 to 15 g/m3, the corona onset voltage increases slowly. Furthermore, the lower air pressure is, the more obvious effect of absolute humidity on the corona onset voltage is. Yet, the corona onset voltage drops remarkably when absolute humidity reaches 17.3 g/m3, owing to the condensation, which distorts the surface electric field, on the surface of conductors under high-humidity condition. In light of the condensation effect, the mathematical model of corona discharge is improved, which helps yield agreement between the measured results and the calculated results. Moreover, formulas for predicting corona onset voltages under various bundle configurations, air pressure and air humidity are also obtained. Calculated results from these formulas along with from mathematical models are compared with the measured results.
References
-
-
1)
-
Calva, P., Espino, C.: `Effect of the humidity in the ionic mobility in reduced air-density', Conf. on Electrical Insulation and Discharge Phenomena, October 1998, Atlanta, USA, 2, p. 508–511.
-
2)
-
GB/T 775.2–2003: ‘Test method for insulators – part 2: electrical test methods’, 2003.
-
3)
-
Q. Wang ,
L. Zhang ,
Z. Li
.
Influence of humidity on conductor corona onset voltage.
Electr. Power Constr.
,
8 ,
38 -
41
-
4)
-
P. Ortéga ,
R. Díaz ,
F. Heilbronner ,
F. Rühling
.
Influence of negative ions on the humidity effect on the first corona inception.
J. Phys. D, Appl. Phys.
,
22 ,
7000 -
7007
-
5)
-
X. Bian ,
J. Hui ,
H. Huang ,
L. Wang ,
Z. Guan ,
Y. Chen
.
Effects of air pressure and humidity on the characteristics of negative DC corona.
Proc. CSEE
,
4 ,
118 -
124
-
6)
-
J. Lowke ,
F. Alessandro
.
Onset corona fields and electrical breakdown criterion.
J. Phys. D, Appl. Phys.
,
21 ,
2673 -
2682
-
7)
-
Z. Li ,
G. Li ,
J. Fan ,
Z. Su ,
C. Gu
.
Numerical calculations of monopolar corona from the bare bundle conductors of HVDC transmission lines.
IEEE Trans. Power Deliv.
,
3 ,
1579 -
1585
-
8)
-
M. Abdel-Salam ,
A. Turky ,
A. Hashem
.
The onset voltage of coronas on bare and coated conductors.
J. Phys. D, Appl. Phys.
,
45 ,
2550 -
2556
-
9)
-
IEC 60060–1 ed2.0: ‘High-voltage test techniques – part 1: general definitions and test requirements’, 1989.
-
10)
-
Z. Al-Hamouz ,
M. Abdel-Salam
.
Finite-element solution of monopolar corona on bundle conductors.
IEEE Trans. Ind. Appl.
,
2 ,
380 -
386
-
11)
-
A. Robledo-Martnez
.
Characteristics of DC corona discharge in humid, reduced-density air.
J. Electrostat.
,
2 ,
101 -
111
-
12)
-
Q. Fei ,
D. Yue ,
G. Wu ,
B. Wan
.
The influence of the surface free engergy on the performance of air Collers.
J. Dalian Marit. Univ.
,
4 ,
92 -
95
-
13)
-
GB/T 2317.2–2000: ‘Corona and RIV tests for electric power fittings’, 2000.
-
14)
-
M. Abdel-Salam
.
Positive wire-to-plane coronas as influenced by atmospheric humidity.
IEEE Trans. Ind. Appl.
,
1 ,
35 -
40
-
15)
-
Y. Liu ,
J. Li ,
B. Li
.
Effect of air density and humidity on conductor corona performances.
Power Syst. Technol.
,
4 ,
46 -
50
-
16)
-
L. Shu ,
X. Lai ,
D. Yu
.
Influence of atmospheric pressure on dc positive corona discharge in icicle to iced plate electrode system.
Proc. CSEE
,
7 ,
116 -
120
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2010.0560
Related content
content/journals/10.1049/iet-gtd.2010.0560
pub_keyword,iet_inspecKeyword,pub_concept
6
6