© The Institution of Engineering and Technology
Monitoring generator oscillations using Prony analysis is an application that is being increasingly implemented using phasor measurement units (PMUs) data. Most of the existing literature for power system oscillations using Prony method report implementing fixed sampling window that is obtained following a systematic iterative approach taking into account potential disturbances. The fixed sampling technique, although simple to implement, does not optimise the data acquisition time. Moreover, sampling using inadequate intervals can potentially lead to errors during Prony analysis. In this study mathematical formulations are derived to show the effect of small and large sampling intervals. Further, a technique using condition number is proposed as a quality index for signalling the errors arising because of the choice of sampling interval. To facilitate an efficient monitoring rate, while still maintaining sufficient accuracy, an adaptive sampling scheme is proposed. This study demonstrates that the proposed scheme can potentially exhibit faster monitoring rate with acceptable accuracy during practical implementation.
References
-
-
1)
-
Koessler, R.J., Prabhakara, F.S., Al-Mubarak, A.H.: `Analysis of oscillations with eigen analysis and Prony techniques', IEEE Power Engineering Society General Meeting, 2007.
-
2)
-
G.E.P. Box ,
G.M. Jenkins ,
G.C. Reinsel
.
(1994)
Time series analysis: forecasting and control.
-
3)
-
(2007)
Wide area monitoring and control for transmission capability enhancement.
-
4)
-
M. Chakraborty ,
H.C. So ,
J. Zheng
.
New adaptive algorithm for delay estimation of sinusoidal signals.
IEEE Signal Process. Lett.
,
12 ,
984 -
987
-
5)
-
G. Rogers
.
(2000)
Power system oscillations.
-
6)
-
Vien, A.: `Practical numerical issues in industrial identification', 1994, PhD, University of Alberta.
-
7)
-
J.F. Hauer ,
C.J. Demeure ,
L.L. Scharf
.
Initial results in Prony analysis of power system response signal.
IEEE Trans. Power Syst.
,
1 ,
80 -
89
-
8)
-
P. Korba
.
Real-time monitoring of electromechanical oscillations in power systems: first findings.
IET Gener. Transm. Distrib.
,
80 -
88
-
9)
-
Xiao, J., Han, Y., Wu, J.: `Dynamic tracking of low-frequency oscillations with improved Prony method in wide-area measurement system', IEEE Power Engineering Society General Meeting, 2004.
-
10)
-
J.-Z. Yang ,
C.-W. Liu ,
W.-G. Wu
.
A hybrid method for the estimation of power system low-frequency oscillation parameters.
IEEE Trans. Power Syst.
,
4 ,
2115 -
2123
-
11)
-
J.-H. Lee ,
H.-T. Kim
.
Selecting sampling interval of transient response for the improved Prony method.
IEEE Trans. Antennas Propag.
,
1 ,
74 -
77
-
12)
-
G.H. Golub ,
C.F. Van Loan
.
(1989)
Matrix computations.
-
13)
-
Y. Hua ,
T.K. Sarkar
.
Matrix pencil method for estimating parameters of exponentially damped/undamped sinusoids in noise.
IEEE Trans. Acoust. Speech Signal Process.
,
5 ,
814 -
824
-
14)
-
La Scala, M., De Benedictis, M., Bruno, S.: `Development of applications in WAMS and WACS: an international cooperation experience', IEEE Power Engineering Society General Meeting, 2006.
-
15)
-
P. Kundur
.
(1994)
Power system stability and control.
-
16)
-
Restrepo, J.Q.: `A real-time wide-area control for mitigating small-signal instability in large electric power systems', 2005, PhD, Washington State University.
-
17)
-
D.A. Pierre ,
D.J. Trudnowski ,
J.F. Hauer
.
Identifying linear reduced-order models for systems with arbitrary initial conditions using Prony signal analysis.
IEEE Trans. Autom. Control
,
6 ,
831 -
835
-
18)
-
Johnson, M.A., Zarafonitis, I.P.: `Prony analysis and power system stability some recent theoretical and applications research', IEEE Power Engineering Society Summer Meeting, 2000, 3, p. 1918–1923.
-
19)
-
A.J. Poggio ,
M.L. Van Blaricum ,
E.K. Miller ,
R. Mittra
.
Evaluation of a processing technique for transient data.
IEEE Trans. Electromagn. Compat.
,
1 ,
165 -
173
-
20)
-
D. Cirio ,
A. Danelli ,
M. Pozzi ,
S. Cecere ,
G. Giannuzzi ,
M. Sforna
.
(2006)
Wide area monitoring and control system: the Italian research and development.
-
21)
-
R.W. Kulp
.
An optimum sampling procedure for use with the Prony method.
IEEE Trans. Electromagn. Compat.
,
2 ,
67 -
71
-
22)
-
E. Kreyszig
.
(2006)
Advance engineering mathematics.
-
23)
-
A. Bracale ,
P. Caramia ,
G. Carepinelli
.
Adaptive Prony method for waveform distortion detection in power systems.
Int. J. Electr. Power Energy Syst.
,
371 -
379
-
24)
-
Huang, Y., Xu, Z., Pan, W.: `A practical analysis method of low frequency oscillation for large power system', IEEE Power Engineering Society General Meeting, 2005, 2, p. 1623–1629.
-
25)
-
C.W. Taylor ,
D.C. Erickson ,
K.E. Martin ,
R.E. Wilson ,
V. Venkatasubramanian
.
WACS-wide-area stability and voltage control system: R&D and online demonstration.
Proc. IEEE
,
5 ,
892 -
906
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2009.0174
Related content
content/journals/10.1049/iet-gtd.2009.0174
pub_keyword,iet_inspecKeyword,pub_concept
6
6