access icon free Understanding and analysis on frequency dielectric parameter for quantitative diagnosis of moisture content in paper–oil insulation system

The ageing rate of cellulose insulation materials (paper/pressboard) in oil-impregnated transformers is largely determined by moisture. In this paper, several experiments were conducted under controlled laboratory conditions to quantitatively diagnose the amount of moisture in cellulose insulation using frequency domain spectroscopy (FDS) technique, which has been proven to be an effective tool to predict the insulation condition in oil-impregnated power equipment. The frequency dielectric response in oil-impregnated pressboards, moisture content as well as test temperature, was monitored carefully, and a new dielectric characteristic parameter for the diagnosis of moisture content was proposed. In addition, the master curve technique was introduced to calibrate the temperature effect on FDS measurement results. These experiments revealed that a strong correlation exists between frequency dielectric parameter and moisture content in cellulose insulation. Such correlation can be utilised for better prediction of moisture content in paper–oil insulation. A modified assessment method for the diagnosis of moisture content in paper–oil insulation was investigated and its effectiveness was also demonstrated using a case.

Inspec keywords: transformer oil; paper; frequency-domain analysis; spectroscopy

Other keywords: ageing rate; test temperature; moisture content diagnosis; oil-impregnated pressboards; paper-oil insulation system; controlled laboratory conditions; master curve technique; quantitative diagnosis; oil-impregnated transformers; paper; dielectric characteristic parameter; moisture content; insulation condition prediction; frequency domain spectroscopy technique; pressboard; oil-impregnated power equipment; frequency dielectric parameter; cellulose insulation materials; frequency dielectric response; moisture content prediction; FDS measurement; FDS technique

Subjects: Organic insulation; Inductors and transformers; Transformers and reactors

References

    1. 1)
    2. 2)
    3. 3)
    4. 4)
    5. 5)
    6. 6)
    7. 7)
    8. 8)
      • 22. Chen, J.D., Liu, Z.Y.: ‘Dielectric physics’ (China Machine Press, 1982).
    9. 9)
      • 20. Jonscher, A.K.: ‘Universal relaxation law’ (Chelsea Dielectrics Press, 1996).
    10. 10)
    11. 11)
    12. 12)
    13. 13)
    14. 14)
    15. 15)
    16. 16)
    17. 17)
      • 19. Aradhana, R., Sridhar, S., Papneja, G.S.: ‘Moisture and dielectric properties analysis of power transformer by DIRANA measurement’, Water Energy Int., 2010, 67, (1), pp. 333344.
    18. 18)
      • 3. Liao, R.J., Liang, S.W., Sun, C.X., Yang, L.J., Sun, H.G.: ‘A comparative study of thermal aging of transformer insulation paper impregnated in natural ester and in mineral oil’, Eur. Trans. Electr. Power, 2010, 20, (4), pp. 518533.
    19. 19)
    20. 20)
    21. 21)
    22. 22)
      • 28. Koch, M., Krüger, M.: ‘A fast and reliable dielectric diagnostic method to determine moisture in power transformers’. Proc. Int. Conf. on Condition Monitoring and Diagnosis, Beijing, China, April 2008, pp. 467470.
    23. 23)
    24. 24)
    25. 25)
    26. 26)
      • 26. Pahlavanpour, B., Martins, M., Eklund, : ‘Study of moisture equilibrium in oil-paper system with temperature variation’. Proc. Int. Conf. on Properties Applications of Dielectric Materials, June 2003, pp. 11241129.
    27. 27)
    28. 28)
      • 24. Jonscher, A.K.: ‘Dielectric relaxation in solids’ (Chelsea Dielectrics Press, London, UK, 1983).
    29. 29)
    30. 30)
      • 21. Liao, R.J., Hao, J., Yang, L.J., Yuan, Q., Tang, C.: ‘Relationship between frequency domain dielectric characteristic quantity and aging status of transformer oil-paper insulation’, Trans. Chin. Electrotechn. Soc., 2012, 27, (5), pp. 4376.
    31. 31)