High-speed analogue sampled-data signal processing for real-time fault location in electrical power networks

High-speed analogue sampled-data signal processing for real-time fault location in electrical power networks

For access to this article, please select a purchase option:

Buy eFirst article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
— Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The emulation of low-loss or lossless one-dimensional (1D) or 2D transmission mediums using analogue sampled-data signal processing is presented. Based on discrete-time wave propagation simulation, transmission lines are emulated with many elementary identical delay elements, implemented by simple equivalent switched-capacitor (SC) circuits. The accuracy and limitations of this discrete time model are studied in the frame of power network fault location using electromagnetic time-reversal principle. The sensitivities to non-ideal effects usually plaguing analogue CMOS SC circuits, such as amplifier finite open-loop gain, offset, and parasitic charge injection due to clock feedthrough, are evaluated in the same context. It is shown that the SC line emulation is well suited to the presented fault location technique and considerably reduces the fault location time (by a factor up to 100) in comparison to standard digital solutions, allowing fault location resolutions of typically 1% within a few hundred milliseconds. These expectations are confirmed by measurements realised on the presented line model integrated-circuit, implemented in an AMS 0.35 μm CMOS process. The speed improvement obtained through the presented method is essential, potentially allowing real-time fault management in power grids.