access icon free Analysis of diurnal changes in pupil dilation and eyelid aperture

This work is inspired by the observation of surprising daily fluctuations in the number of valid iris code bits used to match irises in the NEXUS program operated by the Canadian Border Security Agency. These fluctuations have an impact on iris comparison scores but cannot be simply explained by pupil dilation, which does not have a clear pattern that would generalise to a population. To check if fluctuations in the number of valid iris code bits may be explained by eyelid aperture observed in a controlled, laboratory environment, the eyelid aperture was measured for 18 subjects participating in an acquisition every 2 h during the day. Simultaneously, the pupil dilation was measured to check the existence of a daily pattern for a population and for single subjects. There are two interesting outcomes of this work. First, there are statistically significant changes during the day in both pupil dilation and eyelid opening observed for individual subjects. Second, these changes do not generalise well into a common pattern for the group. Consequently, the diurnal fluctuations in the number of bits compared and the comparison score observed in the NEXUS program cannot be explained by changes in pupil dilation nor by eyelid aperture.

Inspec keywords: eye; national security; image matching; iris recognition

Other keywords: pupil dilation; iris comparison scores; valid iris code bit daily fluctuations; diurnal fluctuations; Canadian Border Security Agency; iris matching; diurnal change analysis; eyelid aperture; NEXUS program

Subjects: Image recognition; National security; Computer vision and image processing techniques

References

    1. 1)
      • 7. Loving, R.T., Kripke, D.F., Glazner, L.K.: ‘Circadian rhythms in the human pupil and eyelid’, Am. J. Physiol. – Regul. Integr. Comp. Physiol., 1996, 271, (2), pp. R320R324.
    2. 2)
      • 1. Canada Border Services Agency. NEXUS Program. Available at http://www.cbsaasfc.gc.ca/prog/nexus/menu-eng.html.
    3. 3)
      • 3. Tomeo-Reyes, I., Ross, A., Chandran, V.: ‘Investigating the impact of drug induced pupil dilation on automated iris recognition’. 2016 IEEE 8th Int. Conf. on Biometrics Theory, Applications and Systems (BTAS), September 2016, pp. 18.
    4. 4)
      • 6. Daugman, J., Downing, C.: ‘Searching for doppelgangers: assessing the universality of the iriscode impostors distribution’, IET Biometrics, 2016, 5, (2), pp. 6575.
    5. 5)
      • 2. Ortiz, E., Bowyer, K.W., Flynn, P.J.: ‘Dilation-aware enrolment for iris recognition’, IET Biometrics, 2016, 5, (2), pp. 9299.
    6. 6)
      • 5. Czajka, A., Bowyer, K.W.: ‘Statistical evaluation of up-to-three-attempt iris recognition’. 2015 IEEE 7th Int. Conf. on Biometrics Theory, Applications and Systems (BTAS), September 2015, pp. 16.
    7. 7)
      • 9. Bowyer, K.W., Ortiz, E.: ‘Pitfalls in studying big data from operational scenarios’. 8th IEEE Int. Conf. on Biometrics: Theory, Applications, and Systems, September 2016, pp. 16.
    8. 8)
      • 10. Grother, P.J., Matey, J.R., Tabassi, E., et al: ‘IREX VI – temporal stability of iris recognition accuracy’. NIST Interagency/Internal Report (NISTIR) 7948, 2013. Available at http://www.nist.gov/manuscript-publicationsearch.cfm?pub id=913900.
    9. 9)
      • 4. Ortiz, E., Bowyer, K.W.: ‘Exploratory analysis of an operational iris recognition dataset from a CBSA border-crossing application’. 2015 IEEE Conf. on Computer Vision and Pattern Recognition Workshops (CVPRW), June 2015, pp. 3441.
    10. 10)
      • 8. Burrow, J.G.: ‘Is diurnal variation a factor in bare footprint formation?’, J. Forensic Identif., 2016, 66, (2), pp. 107117.
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-bmt.2016.0191
Loading

Related content

content/journals/10.1049/iet-bmt.2016.0191
pub_keyword,iet_inspecKeyword,pub_concept