access icon openaccess Influence of moisture on the interface charge of oil–pressboard composite insulation under DC voltage

  • PDF
    1.8645496368408203MB
  • XML
    64.890625Kb
  • HTML
    63.9033203125Kb
Loading full text...

Full text loading...

/deliver/fulltext/hve/3/1/HVE.2017.0096.html;jsessionid=2oe01v2khdkjo.x-iet-live-01?itemId=%2fcontent%2fjournals%2f10.1049%2fhve.2017.0096&mimeType=html&fmt=ahah

References

    1. 1)
      • 1. Yuxian, L.: ‘Moisture content analysis of oil–paper insulation in transformer and its influence on operation safety’, Transformer, 2002, 39, (5), pp. 16, doi: 10.3969/j.issn.1001-8425.2002.05.001.
    2. 2)
      • 2. Hui, W., Yuan, Y., Cheng Rong, L., et al: ‘Influence of micro water on partial discharge between windings in transformers’, High Volt. Eng.., 2010, 36, (5), pp. 11431149.
    3. 3)
      • 3. Emsley, A.M., Xiao, X., Heywood, R.J., et al: ‘Degradation of cellulosic insulation in power transformers. Part 3: effects of oxygen and water on aging in oil’, IEE Proc. Sci. Meas. technol., 2000, 147, (3), pp. 115119, doi: 10.1049/ip-smt:20000021.
    4. 4)
      • 4. Ruijin, L., Jian, H., Shuaiwei, L., et al: ‘Influence of water and acid on the thermal aging of mineral oil mixed with natural ester oil–paper insulation’, Trans. China Electro Tech. Soc., 2010, 25, (7), pp. 3136.
    5. 5)
      • 5. Yuxian, L.: ‘Water accumulation in oil–paper insulation transformer and its influence to life time’, Transformer., 2004, 41, (2), pp. 812, doi: 10.3969/j.issn.1001-8425.2004.02.003.
    6. 6)
      • 6. Caixin, S., Qu, Z., Lin, D., et al: ‘The real time monitor of water content in transformer oil’, High Volt. Eng., 1998, 24, (1), pp. 6466, doi: 10.3969/j.issn.1001-8425.2002.z1.018.
    7. 7)
      • 7. Wei, W.: ‘Impact of aging and moisture on creepage discharges on oil impregnated pressboard’. PhD thesis, North China Electric Power University, 2012.
    8. 8)
      • 8. Kai, W., Qing-dong, Z., Xi, C., et al: ‘Effect of temperature gradient on space charge distribution in oil impregnated papers’, High Volt. Eng., 2011, 37, (4), pp. 823827.
    9. 9)
      • 9. Yun-shan, W., Yuan-Xiang, Z., Guang-Fan, L., et al: ‘Space charge phenomena in oil–paper insulation materials under high voltage direct current’, High Volt. Eng., 2008, 34, (5), pp. 873877.
    10. 10)
      • 10. Yuan-xiang, Z., Meng, H., Wei-jiang, C., et al: ‘Space charge characteristics of the interface in oil–paper insulation under DC voltage’, High Volt. Eng., 2011, 37, (10), pp. 24172423.
    11. 11)
      • 11. Rongsheng, L., Albert, J.: ‘Moisture and space charge in oil impregnated pressboard under HVDC’. IEEE Int. Conf. Conduction and Breakdown in Solid Dielectrics ABB Forum, Vateras, Sweden, 1998, pp. 1722.
    12. 12)
      • 12. Jian, H., Jia, G., Rui-jin, C.L., et al: ‘Moisture effects on the space charge of oil–paper insulation under DC voltage’. 13th National Conf. Engineering Dielectrics, Xi'an, 2011, pp. 232236.
    13. 13)
      • 13. Maeno, T., Nonaka, Y., Takada, T.: ‘Determination of electric field distribution in oil using the Kerr-effect technique after application of DC voltage’, IEEE Trans. Electr. Insul., 1990, 25, (3), pp. 475480, doi: 10.1109/14.55719.
    14. 14)
      • 14. Nonaka, Y., Sato, H., Maeno, T., et al: ‘Electric field in transformer oil measured with the Kerr-effect technique’, IEEE Trans. Electr. Insul., 1991, 26, (2), pp. 210216, doi: 10.1109/14.78319.
    15. 15)
      • 15. Tanaka, K., Takada, T.: ‘Measurement of the two-dimensional electric field vector in dielectric liquids’, IEEE Trans. Dielectr. Electr. Insul., 1994, 1, (4), pp. 747753, doi: 10.1109/94.311720.
    16. 16)
      • 16. Maeno, T., Takada, T.: ‘Electric field measurement in liquid dielectrics using a combination of AC voltage modulation and a small retardation angle’, IEEE Trans. Electr. Insul., 1987, 22, (4), pp. 503508, doi: 10.1109/tei.1987.298916.
    17. 17)
      • 17. Qi, B., Zhao, X., Li, C., et al: ‘Electric field distribution in oil–pressboard insulation under AC–DC combined voltages’, IEEE Trans. Dielectr. Electr. Insul., 2016, 23, (4), pp. 19351941, doi: 10.1109/tdei.2016.7556464.
    18. 18)
      • 18. Qi, B., Zhao, X., Li, C., et al: ‘Transient electric field characteristics in oil–pressboard composite insulation under voltage polarity reversal’, IEEE Trans. Dielectr. Electr. Insul., 2015, 22, (4), pp. 21482155, doi: 10.1109/tdei.2015.004347.
    19. 19)
      • 19. Du, Y., Zahn, M., Lesieutm, B.C., et al: ‘Moisture equilibrium in transformer paper–oil systems’, IEEE Electr. Insul. Mag., 1999, 15, (1), pp. 1120, doi: 10.1109/57.744585.
    20. 20)
      • 20. Garcia, B., Burgos, J.C., Alonso, A.M., et al: ‘A moisture-in-oil model for power transformer monitoring – part I: theoretical foundation’, IEEE Trans. Power Deliv., 2005, 20, (2), pp. 14171422, doi: 10.1109/tpwrd.2004.832366.
    21. 21)
      • 22. Kato, K., Okubo, H., Endo, F., et al: ‘Investigation of charge behavior in low viscosity silicone liquid by Kerr electro-optic field measurement’, IEEE Trans. Dielectr. Electr. Insul., 2010, 17, (4), pp. 12141220, doi: 10.1109/tdei.2010.5539692.
    22. 22)
      • 23. Ieda, M., Goto, K., Okugo, H., et al: ‘Suppression of static electrification of insulation oil for large power transformers’, IEEE Trans. Electr. Insul., 1988, 23, (1), pp. 153157, doi: 10.1109/14.2349.
    23. 23)
      • 24. GB1410-2006: ‘Methods of volume resistivity and surface resistivity of solid insulating materials’, 2006.