Range-of-motion (ROM) assessment is a critical assessment tool during the rehabilitation process. The conventional approach uses the goniometer which remains the most reliable instrument but it is usually time-consuming and subject to both intra- and inter-therapist measurement errors. An automated wireless wearable sensor system for the measurement of ROM has previously been developed by the current authors. Presented is the correlation and accuracy of the automated wireless wearable sensor system against a goniometer in measuring ROM in the major joints of upper (UEs) and lower extremities (LEs) in 19 healthy subjects and 20 newly disabled inpatients through intra (same) subject comparison of ROM assessments between the sensor system against goniometer measurements by physical therapists. In healthy subjects, ROM measurements using the new sensor system were highly correlated with goniometry, with 95% of differences < 20° and 10° for most movements in major joints of UE and LE, respectively. Among inpatients undergoing rehabilitation, ROM measurements using the new sensor system were also highly correlated with goniometry, with 95% of the differences being < 20° and 25° for most movements in the major joints of UE and LE, respectively.
References
-
-
1)
-
5. Ferriero, G., Vercelli, S., Sartorio, F., et al: ‘Reliability of a smartphone-based goniometer for knee joint goniometry’, Int. J. Rehabil. Res., 2012, .
-
2)
-
15. Lee, W.W., Yen, S.C., Tay, A., et al: ‘A smartphone-centric system for range of motion assessment in stroke patients’, IEEE J. Biomed. Health Inform., 2014, 18, (6), pp. 1839–1847 (doi: 10.1109/JBHI.2014.2301449).
-
3)
-
19. Bland, J.M., Altman, D.G.: ‘Comparing methods of measurement: why plotting difference against standard method is misleading’, Lancet, 1995, 346, pp. 1085–1087 (doi: 10.1016/S0140-6736(95)91748-9).
-
4)
-
11. Gibbs, P.T., Asada, H.H.: ‘Wearable conductive fiber sensors for multi-axis human joint angle measurements’, J. Neuroeng. Rehabil., 2005, 2, (7), pp. 1743–1746.
-
5)
-
14. Watanabe, T., Saito, H.: ‘Tests of wireless wearable sensor system in joint angle measurement of lower limbs’. Conf. Proc. IEEE Engineering in Medicine Biology Society, Boston, MA, USA, September 2011, pp. 5469–5472.
-
6)
-
7. Chapleau, J., Canet, F., Petit, Y., Laflamme, G.Y., Rouleau, D.M.: ‘Validity of goniometric elbow measurements: comparative study with a radiographic method’, Clin. Orthopaedics Relat. Res., 2011, 469, pp. 3134–3140 (doi: 10.1007/s11999-011-1986-8).
-
7)
-
12. Bland, J.M., Altman, D.G.: ‘Statistical methods for assessing agreement between two methods of clinical measurement’, Lancet, 1986, 1, (8476), pp. 307–310 (doi: 10.1016/S0140-6736(86)90837-8).
-
8)
-
8. Draper, C.E., Chew, K.T., Wang, R., Jennings, F., Gold, G.E., Fredericson, M.: ‘Comparison of quadriceps angle measurements using short-arm and long-arm goniometers: correlation with MRI’, PM&R, 2011, 3, pp. 111–116.
-
9)
-
16. Clarkson, H.M.: ‘Musculoskeletal assessment: joint range of motion and manual muscle strength’ (Lippincott Williams & Wilkins, USA, 2000, 2nd edn.).
-
10)
-
13. Goodvin, C., Park, E.J., Huang, K., Sakaki, K.: ‘Development of a real-time three-dimensional spinal motion measurement system for clinical practice’, Med. Biol. Eng. Comput., 2006, 44, pp. 1061–1075 (doi: 10.1007/s11517-006-0132-3).
-
11)
-
3. Van De Pol, R.J., Van Trijffel, E., Lucas, C.: ‘Inter-rater reliability for measurement of passive physiological range of motion of upper extremity joints is better if instruments are used: a systematic review’, J. Physiother., 2010, 56, pp. 7–17 (doi: 10.1016/S1836-9553(10)70049-7).
-
12)
-
4. Hellebrandt, F.A., Duvall, E.N., Moore, M.L.: ‘The measurement of joint motion: part III. Reliability of goniometry’, Phys. Ther. Rev., 1949, 29, pp. 302–307.
-
13)
-
12. Dejnabadi, H., Jolles, B.M., Aminian, K.: ‘A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes’, IEEE Trans. Biomed. Eng., 2005, 52, pp. 1478–1484 (doi: 10.1109/TBME.2005.851475).
-
14)
-
10. Liu, K., Liu, T., Shibata, K., Inoue, Y., Zheng, R.: ‘Novel approach to ambulatory assessment of human segmental orientation on a wearable sensor system’, J. Biomech., 2009, 42, pp. 2747–2752 (doi: 10.1016/j.jbiomech.2009.08.008).
-
15)
-
20. Kolber, M.J., Hanney, W.J.: ‘The reliability and concurrent validity of shoulder mobility measurements using a digital inclinometer and goniometer: a technical report’, Int. J. Sports Phys. Ther., 2012, 7, pp. 306–313.
-
16)
-
6. Hoffmann, T., Russell, T., Cooke, H.: ‘Remote measurement via the internet of upper limb range of motion in people who have had a stroke’, J. Telemed. Telecare, 2007, 13, pp. 401–405 (doi: 10.1258/135763307783064377).
-
17)
-
2. Blonna, D., Zarkadas, P.C., Fitzsimmons, J.S., O'Driscoll, S.W.: ‘Accuracy and inter-observer reliability of visual estimation compared to clinical goniometry of the elbow’, Knee Surg. Sports Traumatol. Arthrosc., 2012, 20, pp. 1378–1385 (doi: 10.1007/s00167-011-1720-9).
-
18)
-
1. Gajdosik, R.L., Bohannon, R.W.: ‘Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity’, Phys. Ther., 1987, 67, pp. 1867–1872.
-
19)
-
17. Taylor, R.: ‘Interpretation of the correlation coefficient: a basic review’, J. Diagn. Med. Sonography, 1990, 1, pp. 35–39 (doi: 10.1177/875647939000600106).
-
20)
-
B. Najafi ,
K. Aminian ,
A. Paraschiv-Ionescu ,
F. Loew ,
C. Büla ,
P. Robert
.
Ambulatory system for human motion analysis using a kinematic sensor: monitoring of daily physical activity in the elderly.
IEEE Trans. Biomed. Eng.
,
6 ,
711 -
723
-
21)
-
21. Peeler, J., Anderson, J.E.: ‘Reliability of the Ely's test for assessing rectus femoris muscle flexibility and joint range of motion’, J. Orthopaedic Res., 2008, 26, pp. 793–799 (doi: 10.1002/jor.20556).
http://iet.metastore.ingenta.com/content/journals/10.1049/htl.2014.0100
Related content
content/journals/10.1049/htl.2014.0100
pub_keyword,iet_inspecKeyword,pub_concept
6
6