This is an open access article published by the IET under the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/)
The global trend for increasing life expectancy is resulting in aging populations in a number of countries. This brings to bear a pressure to provide effective care for the older population with increasing constraints on available resources. Providing care for and maintaining the independence of an older person in their own home is one way that this problem can be addressed. The EU Funded Unobtrusive Smart Environments for Independent Living (USEFIL) project is an assistive technology tool being developed to enhance independent living. As part of USEFIL, a wrist wearable unit (WWU) is being developed to monitor the physical activity (PA) of the user and integrate with the USEFIL system. The WWU is a novel application of an existing technology to the assisted living problem domain. It combines existing technologies and new algorithms to extract PA parameters for activity monitoring. The parameters that are extracted include: activity level, step count and worn state. The WWU, the algorithms that have been developed and a preliminary validation are presented. The results show that activity level can be successfully extracted, that worn state can be correctly identified and that step counts in walking data can be estimated within 3% error, using the controlled dataset.
References
-
-
1)
-
19. S.C. Ying, H., Schnitzer, A., Leonhardt, S., Schiek, M.: ‘Automatic step detection in the accelerometer signal’. Body Sensor Networks BSN2007, Aachen, Germany, March 2007.
-
2)
-
3)
-
6. Amor, J.D., Ahanathapillai, V., James, C.J.: ‘Detecting and analyzing activity levels for the wrist wearable unit in the USEFIL project’. Proc. XIII Mediterranean Conf. Medical and Biological Engineering and Computing, Seville, Spain, September 2014, pp. 1201–1204.
-
4)
-
10. World Health Organization: .
-
5)
-
2. Humphereys, G.: ‘The health-care challenges posed by population ageing’ (Bulletin of the World Health Organization, 2012), vol. 90.
-
6)
-
13. Najafi, B., Aminian, K., Loew, F., Blanc, Y., Robert, P.A.: ‘Measurement of stand-sit and sit-stand transitions using a miniature gyroscope and its application in fall risk evaluation in the elderly’, IEEE Trans. Biomed. Eng., 2002, 49, (8), pp. 843–851 (doi: 10.1109/TBME.2002.800763).
-
7)
-
8)
-
21. Hatano, Y.: ‘Use of the pedometer for promoting daily walking exercise’, Int. Council Health Phys. Educ. Recreat., 1993, 29, pp. 4–8.
-
9)
-
9. Prince, S.A., Adamo, K.B., Hamel, M.E., Hardt, J., Gorber, S.C., Tremblay, M.: ‘A comparison of direct versus self-report measures for assessing physical activity in adults: a systematic review’, Int. J. Behav. Nutrition Phys. Activity, 2008, 5 (doi: 10.1186/1479-5868-5-56).
-
10)
-
12. Murphy, S.L.: ‘Review of physical activity measurement using accelerometers in older adults: considerations for research design and conduct’, Prev. Med., 2009, 48, pp. 108–114 (doi: 10.1016/j.ypmed.2008.12.001).
-
11)
-
14. Amor, J.D.: ‘Detecting and monitoring behavioural change through personalised ambient monitoring’. , Institute of Sound and Vibration Research, University of Southampton, 2011.
-
12)
-
15. Easton, C., Philip, N., Aleksandravicius, A., et al: ‘Validity of smartphone accelerometers for assessing energy expenditure during fast running’. XIII Mediterranean Conf. on Medical and Biological Engineering and Computing 2013, Seville, Spain, September 2013, pp. 1911–1914.
-
13)
-
1. World Health Organization: .
-
14)
-
J. Pan ,
W.J. Tompkins
.
A real-time QRS detection algorithm.
IEEE Trans. Biomed. Eng.
,
3 ,
230 -
236
-
15)
-
16)
-
16. S.-S.C. Bravata, D.M., Sundaram, V., Gienger, A.L., et al: ‘Using pedometers to increase physical activity and improve health: a systematic review’, JAMA, 2007, 298, pp. 2296–2304 (doi: 10.1001/jama.298.19.2296).
-
17)
-
17. Leidy, N.K., Kimel, M., Ajagbe, L., Kim, K., Hamilton, A., Becker, K.: ‘Designing trials of behavioral interventions to increase physical activity in patients with copd: insights from the chronic disease literature’, Respir. Med., 2014, 108, (3), pp. 472–481 (doi: 10.1016/j.rmed.2013.11.011).
-
18)
-
5. Amor, J.D., James, C.J.: ‘Personalised ambient monitoring: accelerometry for activity level classification’. 4th European Conf. Int. Federation for Medical and Biological Engineering, Antwerp, Belgium, November 2009.
-
19)
-
20. Marschollek, M., Goevercin, M., Wolf, K.H., et al: ‘A performance comparison of accelerometry-based step detection algorithms on a large, non-laboratory sample of healthy and mobility-impaired persons’. Conf. Proc. IEEE Eng Med Biol Soc, 2008, vol. 2008, pp. 1319–22.
-
20)
-
11. Berlin, J.E., Storti, K.L., Brach, J.S.: ‘Using activity monitors to measure physical activity in free-living conditions’, J. Am. Phys. Ther., 2006, 86, pp. 1137–1145.
-
21)
-
3. Grguric, A.: ‘ICT towards elderly independent living’ (Research and Development Centre, Ericsson Nikola Tesla, 2012).
http://iet.metastore.ingenta.com/content/journals/10.1049/htl.2014.0091
Related content
content/journals/10.1049/htl.2014.0091
pub_keyword,iet_inspecKeyword,pub_concept
6
6