Current technologies to allow continuous monitoring of vital signs in pre-term infants in the hospital require adhesive electrodes or sensors to be in direct contact with the patient. These can cause stress, pain, and also damage the fragile skin of the infants. It has been established previously that the colour and volume changes in superficial blood vessels during the cardiac cycle can be measured using a digital video camera and ambient light, making it possible to obtain estimates of heart rate or breathing rate. Most of the papers in the literature on non-contact vital sign monitoring report results on adult healthy human volunteers in controlled environments for short periods of time. The authors' current clinical study involves the continuous monitoring of pre-term infants, for at least four consecutive days each, in the high-dependency care area of the Neonatal Intensive Care Unit (NICU) at the John Radcliffe Hospital in Oxford. The authors have further developed their video-based, non-contact monitoring methods to obtain continuous estimates of heart rate, respiratory rate and oxygen saturation for infants nursed in incubators. In this Letter, it is shown that continuous estimates of these three parameters can be computed with an accuracy which is clinically useful. During stable sections with minimal infant motion, the mean absolute error between the camera-derived estimates of heart rate and the reference value derived from the ECG is similar to the mean absolute error between the ECG-derived value and the heart rate value from a pulse oximeter. Continuous non-contact vital sign monitoring in the NICU using ambient light is feasible, and the authors have shown that clinically important events such as a bradycardia accompanied by a major desaturation can be identified with their algorithms for processing the video signal.
References
-
-
1)
-
6. Abbas, A., Heimann, K., Jergus, K., Orlikowsky, T., Leonhardt, S.: ‘Neonatal non-contact respiratory monitoring based on real-time infrared thermography’, Biomed. Eng. Online, 2011, 10, (1), p. 93 (doi: 10.1186/1475-925X-10-93).
-
2)
-
3. Aarts, L.A., Jeanne, V., Cleary, J.P., et al: ‘Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit – a pilot study’, Early Hum. Dev., 2013, 89, (12), pp. 943–948 (doi: 10.1016/j.earlhumdev.2013.09.016).
-
3)
-
5. Wu, H.Y., Rubinstein, M., Shih, E., Guttag, J., Durand, F., Freeman, W.: ‘Eulerian video magnification for revealing subtle changes in the world’, ACM Trans. Graph., 2012, 31, (4), p. 65 (doi: 10.1145/2185520.2185561).
-
4)
-
10. Godbehere, A., Matsukawa, A., Goldberg, K.: ‘Visual tracking of human visitors under variable-lighting conditions for a responsive audio art installation’. American Control Conf., 2012, pp. 4305–4312.
-
5)
-
4. Klaessens, J.H.G.M., van den Born, M., van der Veen, A.J., et al: ‘Development of a baby friendly non-contact method for measuring vital signs: first results of clinical measurements in an open incubator at a neonatal intensive care unit’. Proc. of SPIE, 2014, vol. 8935, pp. 1–7.
-
6)
-
2. Scalise, L., Bernacchia, N., Ercoli, I., Marchionni, P.: ‘Heart rate measurement in neonatal patients using a webcamera’. IEEE Int. Symp. on Medical Measurements and Applications Proc., 2012, pp. 1–4.
-
7)
-
9. Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D.A., Pugh, C.: ‘Non-contact video-based vital sign monitoring using ambient light and auto-regressive models’, Physiol. Meas., 2014, 35, (5), pp. 807–831 (doi: 10.1088/0967-3334/35/5/807).
-
8)
-
8. Blanik, N., Abbas, A., Venema, B., Blazek, V., Leonhardt, S.: ‘Hybrid optical imaging technology for long-term remote monitoring of skin perfusion and temperature behavior’, J. Biomed. Opt., 2014, 19, (1) (doi: 10.1117/1.JBO.19.1.016012).
-
9)
-
7. Abbas, A., Leonhardt, S.: ‘Intelligent neonatal monitoring based on a virtual thermal sensor’, BMC Med. Imaging, 2014, 14, (1), p. 9 (doi: 10.1186/1471-2342-14-9).
-
10)
-
12. Benaron, D.A., Parachikov, I.H., Friedland, S., Soetikno, R., et al: ‘Continuous, noninvasive, and localized microvascular tissue oximetry using visible light spectroscopy’, Anesthesiology, 2004, 100, (6), pp. 1469–75 (doi: 10.1097/00000542-200406000-00019).
-
11)
-
1. McIntosh, N.: ‘The monitoring of critically ill neonates’, J. Med. Eng. Technol., 1983, 7, (3), pp. 121–129 (doi: 10.3109/03091908309032575).
-
12)
-
M.Z. Poh ,
D.J. McDuff ,
R.W. Picard
.
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation.
Opt. Express
,
10762 -
10774
http://iet.metastore.ingenta.com/content/journals/10.1049/htl.2014.0077
Related content
content/journals/10.1049/htl.2014.0077
pub_keyword,iet_inspecKeyword,pub_concept
6
6