Published data on 2–17 GHz airframe attenuation is augmented by measurement data from a total of six military aircraft, including helicopters. Analysis of the results provides a method of assessing 1–18 GHz airframe attenuation and opens up the possibility of aircraft microwave EMC clearance with minimal testing.