© The Institution of Engineering and Technology
To achieve the maximum current rising rate, second-generation Experimental Advanced Superconducting Tokamak (EAST) plasma vertical displacement active feedback power supply applies voltage control mode while retaining the first-generation current tracking mode. When the power supply outputs high voltage, the accompanied frequent over-current protection will return the power to DC side, which leads to over-voltage protection, so the current limiting protection is applied. Experimental results prove that the voltage mode can greatly improve the ability to suppress vertical unstable displacement of plasma.
References
-
-
1)
-
3. Hong, Y., Haihong, H., Pinjian, Q., Ge, G.: ‘Realization of EAST FCPS inverter of based om bang-bang control’, Power Electron., 2011, 45, (7), pp. 106–107.
-
2)
-
1. Huang, H., Wang, H., Gao, G.: ‘Application of phase-shift PWM in EAST fast control power supply’, IEEE Trans. Appl. Supercond., 2010, 20, (3), pp. 1671–1675 (doi: 10.1109/TASC.2009.2039470).
-
3)
-
4. Haihong, H., Teng, Y., Haixin, W.: ‘Application of a current and voltage mixed control mode for the new fast control power supply at EAST’, Plasma Sci. Technol., 2014, 16, (4), pp. 420–423 (doi: 10.1088/1009-0630/16/4/22).
-
4)
-
2. Haihong, H., Ming, Y., Haixin, W.: ‘Design of controller for new EAST fast control power supply’, Plasma Sci. Technol., 2014, 16, (11), pp. 1068–1073 (doi: 10.1088/1009-0630/16/11/13).