Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

access icon free Suppression of therapeutic interference by using Barker code and adaptive notch filtering for real-time HIFU surgery and ultrasound imaging

Real-time ultrasound imaging during high-intensity focused ultrasound (HIFU) surgery allows for tracking tissue movement and monitoring feedback from a treated target. However, the reflected HIFU interference signals deteriorate the quality of imaging signals received by an imaging transducer during simultaneous therapy and imaging. The purpose of this Letter is to demonstrate that those HIFU interference signals can be significantly reduced in the brightness-mode image by using a coded excitation scheme with adaptive notch filtering. A prototype integrated HIFU/imaging transducer was used to experimentally demonstrate the performance of the proposed method.

References

    1. 1)
      • 1. Blana, A., Walter, B., Rogenhofer, S., Wieland, W.F.: ‘High-intensity focused ultrasound for the treatment of localized prostate cancer: 5-year experience’, J. Urology, 2004, 63, pp. 297300 (doi: 10.1016/j.urology.2003.09.020).
    2. 2)
      • 4. Curiel, L., Souchon, R., Rouvière, O., Gelet, A., Chapelon, J.Y.: ‘Elastography for the follow-up of high-intensity focused ultrasound prostate cancer treatment: initial comparison with MRI’, Ultrasound Med. Biol., 2005, 31, pp. 14611468 (doi: 10.1016/j.ultrasmedbio.2005.06.013).
    3. 3)
      • 2. Ebbini, E.S., Yao, H., Shrestha, A.: ‘Dual-mode ultrasound phased array for image-guided surgery’, Ultrason. Imaging, 2006, 28, pp. 6582 (doi: 10.1177/016173460602800201).
    4. 4)
      • 3. Chan, A.H., Fujimoto, V.Y., Moor, D.E., Martin, R.W., Vaezy, S.: ‘An image-guided high intensity focused ultrasound device for uterine fibroids treatment’, Med. Phys., 2002, 29, pp. 26112620 (doi: 10.1118/1.1513990).
    5. 5)
      • 6. Vaezy, S., Shi, X., Martin, R.W., Chi, E., Nelson, P.I., Bailey, M.R., Crum, L.A.: ‘Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging’, Ultrasound Med. Biol., 2001, 27, pp. 3342 (doi: 10.1016/S0301-5629(00)00279-9).
    6. 6)
      • 5. Owen, N.R., Bailey, M.R., Hossack, J., Crum, L.A.: ‘A method to synchronize high-intensity, focused ultrasound with an arbitrary ultrasound imager’, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 2006, 53, pp. 645650 (doi: 10.1109/TUFFC.2006.1610574).
    7. 7)
      • 7. Glover, J.R.: ‘Adaptive noise canceling applied to sinusoidal interferences’, IEEE Trans. Acoust. Speech Signal Process., 1977, ASSP-25, pp. 484491 (doi: 10.1109/TASSP.1977.1162997).