access icon free MEMS-based flexible capacitive electrode for ECG measurement

A thin and flexible capacitive electrode for recording an electrocardiogram (ECG) signal has been developed. Compared with the conventional wet electrode, the capacitive electrode can work without conductive gel and skin preparation, and serves as a tool of long-term ECG measurement. The designed electrode consists of a sensing plate, an active shield plate and two insulating layers, which is fabricated by the micro-electro-mechanical system process. The test result shows that the capacitive electrode can obtain a high-quality ECG signal that is comparable to the one recorded by the conventional wet electrode. The capacitive electrode can be arbitrarily bent to fit the human torso because of its extremely thin and flexible feature. Moreover, a simple front-end circuit is used to integrate more easily into the measurement system.

References

    1. 1)
      • 7. Prance, R., Debray, A., Clark, T., Prance, H., Nock, M., Harland, C., Clippingdale, A.: ‘An ultra-low-noise electrical-potential probe for human-body scanning’, Meas. Sci. Technol., 2000, 11, pp. 291297 (doi: 10.1088/0957-0233/11/3/318).
    2. 2)
      • 1. Chi, Y.M., Jung, T.P., Cauwenberghs, G.: ‘Dry-contact and noncontact biopotential electrodes: methodological review’, IEEE Rev. Biomed. Eng., 2010, 3, pp. 106119 (doi: 10.1109/RBME.2010.2084078).
    3. 3)
      • 3. Lee, S.M., Sim, K.S., Kim, K.K., Lim, Y.G., Park, K.S.: ‘Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement’, Med. Biol. Eng. Comput., 2010, 48, pp. 447457 (doi: 10.1007/s11517-010-0597-y).
    4. 4)
      • 4. Jung, H.C., Moon, J.H., Baek, D.H., Lee, J.H., Choi, Y.Y., Hong, J.S., Lee, S.H.: ‘CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring’, IEEE Trans. Biomed. Eng., 2012, 59, pp. 14721479 (doi: 10.1109/TBME.2012.2190288).
    5. 5)
      • 6. Chi, Y.M., Cauwenberghs, G.: ‘Micropower non-contact EEG electrode with active common-mode noise suppression and input capacitance cancellation’. Proc. Annual Int. Conf. Engineering Medicine Biology Society EMBC, Minneapolis, MI, USA, September 2009, pp. 42184221.
    6. 6)
      • 2. Searle, A., Kirkup, L.: ‘A direct comparison of wet, dry and insulating bioelectric recording electrodes’, Physiol. Meas., 2000, 21, pp. 271283 (doi: 10.1088/0967-3334/21/2/307).
    7. 7)
      • 5. Spinelli, E., Haberman, M.: ‘Insulating electrodes: a review on biopotential front ends for dielectric skin – electrode interfaces’, Physiol. Meas., 2010, 31, pp. S183S189 (doi: 10.1088/0967-3334/31/10/S03).
http://iet.metastore.ingenta.com/content/journals/10.1049/el.2012.4064
Loading

Related content

content/journals/10.1049/el.2012.4064
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
Correspondence
This article has following corresponding article(s):
in brief
This is a required field
Please enter a valid email address