Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

Equipment commissioning — technical

Equipment commissioning — technical

For access to this article, please select a purchase option:

Buy chapter PDF
£10.00
(plus tax if applicable)
Buy Knowledge Pack
10 chapters for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
High Voltage Power Network Construction — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

Commissioning is not only the final technical stage in power network construction but also one of the most critical. As one highly experienced commissioning engineer once put it, `commissioning is the bucket and shovel stage of a project'. By this, the engineer meant that commissioning cleans up any errors or omissions that have taken place earlier in the project. Perhaps a slight overstatement, but commissioning is certainly that last point at which corrections may be made, thereby ensuring the equipment enters commercial service as a fully compliant design. This chapter will provide a broad overview of commissioning requirements and techniques, covering the most commonly installed types of equipment.

Chapter Contents:

  • 15.1 Commissioning — introduction
  • 15.2 Test procedures and documentation
  • 15.2.1 Test procedures and documentation — overview
  • 15.2.2 Formal commissioning stages
  • 15.3 Substation earthing
  • 15.3.1 Substation earthing resistance
  • 15.3.2 Substation rise of earth potential
  • 15.4 Insulation resistance
  • 15.4.1 Insulation resistance — LV circuitry
  • 15.4.2 Insulation resistance — transformers
  • 15.4.3 Insulation resistance — cables
  • 15.5 Current transformers
  • 15.5.1 Current transformers — requirements
  • 15.5.1.1 Flick test
  • 15.5.1.2 Primary injections
  • 15.5.1.3 CT magnetisation curve
  • 15.5.1.4 CT resistance
  • 15.6 Protection and control equipment tests
  • 15.6.1 Protection and control equipment tests — general
  • 15.6.2 Secondary injection test unit
  • 15.6.2.1 Trip and auxiliary relays — secondary injection
  • 15.6.2.2 IDMT overcurrent relay — secondary injection
  • 15.6.2.3 Distance protection — secondary injection
  • 15.6.2.4 Biased differential feeder protection — secondary injection
  • 15.7 VT supplies
  • 15.7.1 VT wiring — secondary injection
  • 15.8 DC circuitry logic tests
  • 15.8.1 DC logic tests — requirements
  • 15.9 Protection and control — common equipment
  • 15.9.1 Equipment under consideration
  • 15.9.1.1 Busbar protection — general
  • 15.9.1.2 Circuit breaker fail
  • 15.9.1.3 Synchronising scheme
  • 15.9.1.4 Substation control system
  • 15.10 Auto-switching
  • 15.10.1 Auto-switching — general
  • 15.10.1.1 Relay inputs/outputs
  • 15.10.1.2 Off-load simulation tests
  • 15.10.1.3 On-load tests
  • 15.11 HV equipment tests
  • 15.11.1 HV equipment commissioning — general
  • 15.11.1.1 Circuit breakers
  • 15.11.1.2 Power transformer
  • 15.11.1.3 HV cables
  • 15.11.1.4 OHL
  • 15.12 Substation battery systems and DC supplies
  • 15.12.1 Battery system and DC supplies
  • 15.13 Loadability
  • 15.13.1 Loadability test
  • 15.14 Energisation and on-load tests
  • 15.14.1 Circuit energisation and on-load tests — overview
  • 15.14.1.1 Method of energisation
  • 15.14.1.2 Commissioning protections
  • 15.14.1.3 Energisation and soak test
  • 15.14.1.4 Phasing out and synchronising
  • 15.14.1.5 Metering
  • 15.14.1.6 On-load tests
  • 15.15 Substation commissioning overview
  • 15.15.1 Substation commissioning tests and inspections
  • 15.15.1.1 Feeder circuit
  • 15.15.1.2 Transformer circuit
  • 15.15.1.3 Bus section/bus coupler
  • 15.15.1.4 Common equipment
  • 15.15.1.5 Civil structural and building engineering

Inspec keywords: commissioning; electrical installation

Other keywords: equipment commissioning; power network construction

Subjects: Electrical contracting and installation

Preview this chapter:
Zoom in
Zoomout

Equipment commissioning — technical, Page 1 of 2

| /docserver/preview/fulltext/books/po/pbpo110e/PBPO110E_ch15-1.gif /docserver/preview/fulltext/books/po/pbpo110e/PBPO110E_ch15-2.gif

Related content

content/books/10.1049/pbpo110e_ch15
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading