Moisture analysis for power transformers

Moisture analysis for power transformers

For access to this article, please select a purchase option:

Buy chapter PDF
£10.00
(plus tax if applicable)
Buy Knowledge Pack
10 chapters for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
Power Transformer Condition Monitoring and Diagnosis — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

In this chapter, the problem of moisture in transformer insulation is tackled. The physical processes involved in moisture dynamics are first described, then the different methodologies that can be applied to estimate the value of this variable are explained. Finally, the challenges that lie ahead regarding moisture monitoring are discussed.

Chapter Contents:

  • 3.1 Introduction
  • 3.2 Moisture in transformer insulation
  • 3.2.1 Risks associated to the presence of high levels of moisture in transformers
  • 3.2.2 Sources of moisture contamination in transformers
  • 3.2.2.1 Residual moisture
  • 3.2.2.2 Ingress of water from the atmosphere
  • 3.2.2.3 Internal generation of water by the decomposition of cellulose and oil
  • 3.3 Moisture dynamics in transformers
  • 3.3.1 Adsorption and desorption of moisture in cellulosic insulation
  • 3.3.2 Moisture distribution within transformer solid insulation
  • 3.3.3 Solubility of water in oil
  • 3.3.4 Moisture equilibrium between paper and oil
  • 3.3.5 Moisture equilibrium in alternative fluids
  • 3.3.6 Moisture dynamics in a transformer under operation
  • 3.4 Monitoring of moisture content in oil
  • 3.4.1 Periodical sampling of oil
  • 3.4.2 On-line measure of oil moisture with capacitive sensors
  • 3.4.3 Interpretation of the moisture content of oil
  • 3.5 Estimation of the moisture content of solid insulation from moisture in oil measures
  • 3.5.1 Determination of moisture content of paper using the equilibrium charts
  • 3.5.2 Improved methodologies to estimate the moisture content of paper from the measures of moisture content of oil
  • 3.6 Dielectric response methods for the estimation of moisture in solid insulation
  • 3.6.1 Theoretical principles
  • 3.6.2 Frequency dielectric spectroscopy
  • 3.6.3 Recovery voltage method
  • 3.6.4 Polarisation and depolarisation currents
  • 3.7 Conclusions, future trends and challenges
  • References

Inspec keywords: power transformer insulation

Other keywords: moisture analysis; power transformer insulation

Subjects: Insulation and insulating coatings; Transformers and reactors

Preview this chapter:
Zoom in
Zoomout

Moisture analysis for power transformers, Page 1 of 2

| /docserver/preview/fulltext/books/po/pbpo104e/PBPO104E_ch3-1.gif /docserver/preview/fulltext/books/po/pbpo104e/PBPO104E_ch3-2.gif

Related content

content/books/10.1049/pbpo104e_ch3
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address