Partial discharges: keys for condition monitoring and diagnosis of power transformers

Partial discharges: keys for condition monitoring and diagnosis of power transformers

For access to this article, please select a purchase option:

Buy chapter PDF
£10.00
(plus tax if applicable)
Buy Knowledge Pack
10 chapters for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
Power Transformer Condition Monitoring and Diagnosis — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The combination of thermal and electrical stress, in conjunction with the synergic effects of moisture in the insulation, might dramatically reduce the lifetime of a power transformer, which is roughly estimated to be 40 years if properly maintained, meaning that many transformers do not experience any failures before being dismantled. Mechanical stresses during short-circuits can also play a role leading, in the worst case, to the radial buckling of the winding and damage of the connection cables at the bushing terminations. A number of these factors can, in the course of time, give rise to partial discharge (PD) phenomena which can be a cause of failure or a symptom of degradation. PD measurements can be carried out conventionally, following the standards IEC 60270 and IEC 60076. Alternative methods, such as those presented in the IEC TS 62478 standard based on acoustic or ultra-high frequency sensors, have been proposed and might offer better sensitivity, particularly for monitoring purposes, and the capability to locate the PD sources. For all these methods, identification of the PD source is a key to achieve a correct course of action (run, repair and replace).

Chapter Contents:

  • Abstract
  • 2.1 Introduction
  • 2.2 Dielectric materials used in power transformers
  • 2.3 Effects of ageing in insulation systems of power transformers
  • 2.3.1 Thermal stress
  • 2.3.1.1 Cellulose
  • 2.3.1.2 Oil
  • 2.3.2 Mechanical stress
  • 2.3.3 Electrical stress
  • 2.3.3.1 Tracking on barriers
  • 2.3.3.2 Bubbling
  • 2.3.3.3 Incomplete filling of turrets
  • 2.3.3.4 Metallic objects
  • 2.3.3.5 Improper spacing of tap changer conductors
  • 2.3.3.6 Static electrification
  • 2.3.4 Ambient stress
  • 2.3.4.1 Water leaks
  • 2.3.4.2 Moisture transients
  • 2.3.4.3 Insulating particles
  • 2.3.4.4 Metal particles
  • 2.3.4.5 Oxygen and moisture leaks
  • 2.3.4.6 Sludge
  • 2.4 Condition monitoring techniques in power transformers
  • 2.4.1 Electrical measurements
  • 2.4.1.1 ABC circuit
  • 2.4.2 Apparent charge estimation: quasi-integration and calibration
  • 2.4.2.1 Principle of quasi-integration and calibration
  • 2.4.2.2 Limits
  • 2.4.3 PD detection in transformers
  • 2.4.3.1 Circuits for PD detection
  • 2.4.3.2 Interference and noise
  • 2.4.3.3 Inductive sensors
  • 2.4.4 Unconventional methods of partial discharge measurements in power transformers
  • 2.4.4.1 Acoustic
  • 2.4.4.2 Ultra-high frequency
  • 2.4.5 Methods of partial discharge analysis
  • 2.4.5.1 Phase-resolved partial discharge patterns
  • 2.4.5.2 Time –frequency maps
  • 2.4.5.3 Power-ratio maps
  • 2.4.5.4 Key characteristics identification
  • 2.4.5.5 Machine learning
  • 2.4.5.6 Comments on different approaches
  • 2.5 Conclusions
  • Acknowledgements
  • References

Inspec keywords: buckling; condition monitoring; power transformer insulation; IEC standards; partial discharge measurement; transformer windings; thermal stresses

Other keywords: ultrahigh frequency sensors; thermal stress; electrical stress; PD measurements; radial buckling; mechanical stresses; bushing terminations; connection cables; PD source; partial discharge phenomena; insulation; condition monitoring; winding; IEC 60270 standard; synergic effects; power transformer diagnosis; IEC 60076 standard; short-circuits; IEC TS 62478 standard

Subjects: Transformers and reactors; Insulation and insulating coatings; Dielectric breakdown and discharges

Preview this chapter:
Zoom in
Zoomout

Partial discharges: keys for condition monitoring and diagnosis of power transformers, Page 1 of 2

| /docserver/preview/fulltext/books/po/pbpo104e/PBPO104E_ch2-1.gif /docserver/preview/fulltext/books/po/pbpo104e/PBPO104E_ch2-2.gif

Related content

content/books/10.1049/pbpo104e_ch2
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address