Differences in performance between SF6 and vacuum circuit-breakers at distribution voltage levels

Access Full Text

Differences in performance between SF6 and vacuum circuit-breakers at distribution voltage levels

For access to this article, please select a purchase option:

Buy chapter PDF
£10.00
(plus tax if applicable)
Buy Knowledge Pack
10 chapters for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
High Voltage Engineering Testing — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

Author(s): S. M. Ali
Source: High Voltage Engineering Testing,2013
Publication date September 2013

This chapter reviews the circuit-breaker designs which are type tested to IEC 62271-200 and IEC 62271-100 for use on distribution voltages up to 52 kV. The design and service experience of different types of commercially available circuit-breakers are considered. The chapter also discusses some special switching duties and focuses on aspects which are necessary for the selection of circuit-breakers for various duties: for example for switching capacitor banks, capacitive and inductive currents, generators, reactors and synchronised switching of transformers with reactors on the secondary side.

Chapter Contents:

  • 10.1 Introduction
  • 10.2 Circuit-breaker
  • 10.3 Vacuum circuit-breaker
  • 10.4 SF6 gas circuit-breakers
  • 10.5 Puffer circuit-breaker
  • 10.6 Rotating-arc circuit-breaker
  • 10.7 Auto-expansion circuit-breaker
  • 10.8 Operating mechanism
  • 10.9 Choice of correct circuit-breaker for special switching duties
  • 10.10 Capacitive and inductive current switching
  • 10.11 Circuit-breakers for generator circuit switching
  • 10.11.1 DC offset
  • 10.11.2 Current chopping and reignition
  • 10.12 Synchronised switching
  • 10.13 Conclusions and some future developments
  • CIGRE perception of future developments: prepared and compiled by H.M. Ryan
  • Acknowledgements
  • Bibliography
  • Appendices
  • A: Relevant strategic IEC Standard reports
  • B: The impact of new functionalities on substation design (relating to CIGRE published work) - abridged and compiled by H.M. Ryan

Inspec keywords: gas insulated switchgear; SF6 insulation; IEC standards; vacuum circuit breakers

Other keywords: reactor; voltage distribution level; IEC 62271-100 standard; synchronised switching; SF6 circuit-breaker; inductive current; vacuum circuit-breaker; switching capacitor bank; IEC 62271-200 standard; transformer; capacitive current; generator

Subjects: Switchgear

Preview this chapter:
Zoom in
Zoomout

Differences in performance between SF6 and vacuum circuit-breakers at distribution voltage levels, Page 1 of 2

| /docserver/preview/fulltext/books/po/pbpo066e/PBPO066E_ch10-1.gif /docserver/preview/fulltext/books/po/pbpo066e/PBPO066E_ch10-2.gif

Related content

content/books/10.1049/pbpo066e_ch10
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading